351 / 373 page ![]() CHAPTER 15 OPERATING PRECAUTIONS 333 The operation sequence is as follows: (a) When the power-off detect signal is input, the NMI routine starts. (b) Then JR $ instruction is executed as the start of NMI routine, the program is looped to wait STOP. Determine values of R and C so that the delay of STOP behind NMI is longer than the longest interrupt wait period 75 states +10 µs (28.75 µs at 12 MHz operation). Figure 15-3. Control Timing of NMI and STOP Instruction execution NMI STOP VIH VIL 75 states + 10 s or more Hardware STOP mode NMI routine JR $ µ When executing the power off processing before executing the JR $ in the NMI routine, delay of STOP is required to be larger in proportion to time shortened. |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|