Back Button H8/3334Y Datasheet HTML 338Page - Renesas Technology Corp H8/3334Y Datasheet HTML 339Page - Renesas Technology Corp H8/3334Y Datasheet HTML 340Page - Renesas Technology Corp H8/3334Y Datasheet HTML 341Page - Renesas Technology Corp H8/3334Y Datasheet HTML 342Page - Renesas Technology Corp H8/3334Y Datasheet HTML 343Page - Renesas Technology Corp H8/3334Y Datasheet HTML 344Page - Renesas Technology Corp H8/3334Y Datasheet HTML 345Page - Renesas Technology Corp H8/3334Y Datasheet HTML 346Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 342 / 747 page
background image
312
6. Countermeasure
Figure 13.19 shows the recommended program flow.
IRIC = 1?
Read IRIC in ICSR
Read ACKB in ICSR
ACKB = 1?
Read SCL
SCL = 0?
Write 0 to BBSY and
0 to SCP in ICSR
Transmit
data present?
Write data to ICDR
Yes
Yes
No
No
Yes
No
Yes
No
Figure 13.19 Recommended Program Flow
7. Additional Note
When switching from master receive mode to master transmit mode, ensure that TRS is set to 1
before the last receive data is latched by reading ICDR.
8. Precautions when Clearing the IRIC Flag when Using the Wait Function
If the SCL rise time exceeds the specified duration when using the wait function in the I
2C bus
interface’s master mode, or if there is a slave device that keeps SCL low and applies a wait
state, read SCL and clear the IRIC flag only after determining that SCL has gone low, as
shown below.
If the IRIC flag is cleared to 0 when WAIT is set to 1 and while the SCL high level duration is
being extended, the SDA value may change before SCL falls, erroneously resulting in a start or
stop condition.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Scheda tecnica Scarica

Go To PDF Page


Link URL



Lei ha avuto il aiuto da alldatasheet?  [ DONATE ] 

Di alldatasheet   |   Richest di pubblicita   |   contatti   |   Privacy Policy   |   Collegamento alla scheda tecnica    |   scambio Link   |   Ricerca produttore
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com