Motore di ricerca datesheet componenti elettronici
  Italian  ▼
ALLDATASHEETIT.COM

X  

H8/3334Y Scheda tecnica(PDF) 306 Page - Renesas Technology Corp

Il numero della parte H8/3334Y
Spiegazioni elettronici  Single-Chip Microcomputer
PDF  747 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Produttore elettronici  RENESAS [Renesas Technology Corp]
Homepage  http://www.renesas.com
Logo RENESAS - Renesas Technology Corp

H8/3334Y Scheda tecnica(HTML) 306 Page - Renesas Technology Corp

Back Button H8/3334Y Datasheet HTML 302Page - Renesas Technology Corp H8/3334Y Datasheet HTML 303Page - Renesas Technology Corp H8/3334Y Datasheet HTML 304Page - Renesas Technology Corp H8/3334Y Datasheet HTML 305Page - Renesas Technology Corp H8/3334Y Datasheet HTML 306Page - Renesas Technology Corp H8/3334Y Datasheet HTML 307Page - Renesas Technology Corp H8/3334Y Datasheet HTML 308Page - Renesas Technology Corp H8/3334Y Datasheet HTML 309Page - Renesas Technology Corp H8/3334Y Datasheet HTML 310Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 306 / 747 page
background image
276
In receiving, the SCI operates as follows.
1. If an external clock is selected, data is input in synchronization with the input clock. If clock
output is selected, as soon as the RE bit is set to 1 the SCI begins outputting the serial clock
and inputting data. If clock output is stopped because the ORER bit is set to 1, output of the
serial clock and input of data resume as soon as the ORER bit is cleared to 0.
2. Receive data is shifted into RSR in order from LSB to MSB.
After receiving the data, the SCI checks that RDRF is 0 so that receive data can be loaded from
RSR into RDR. If this check passes, the SCI sets RDRF to 1 and stores the received data in
RDR. If the check does not pass (receive error), the SCI operates as indicated in
table 12.10.
Note:
Both transmitting and receiving are disabled while a receive error flag is set. The
RDRF bit is not set to 1. Be sure to clear the error flag.
3. After setting RDRF to 1, if the RIE bit (receive-end interrupt enable) is set to 1 in SCR, the
SCI requests an RXI (receive-end) interrupt. If the ORER bit is set to 1 and the RIE bit in SCR
is set to 1, the SCI requests an ERI (receive-error) interrupt.
When clock output mode is selected, clock output stops when the RE bit is cleared to 0 or the
ORER bit is set to 1. To prevent clock count errors, it is safest to receive one dummy byte and
generate an overrun error.
Figure 12.16 shows an example of SCI receive operation.
Serial clock
Serial data
Bit 0
Bit 1
Bit 7
Bit 0
Bit 1
Bit 6
Bit 7
RXI
request
RDRF
ORER
RXI interrupt
handler reads
data in RDR and
clears RDRF to 0
RXI
request
Overrun error,
ERI request
1 frame
Figure 12.16 Example of SCI Receive Operation



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Scheda tecnica Scarica

Go To PDF Page


Link URL



Lei ha avuto il aiuto da alldatasheet?  [ DONATE ] 

Di alldatasheet   |   Richest di pubblicita   |   contatti   |   Privacy Policy   |   Collegamento alla scheda tecnica    |   scambio Link   |   Ricerca produttore
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com