The **73VR2102-E-R** is a specific model within the **73VR21xx series** of Paperless Recorders manufactured by **M-System**. These devices are used in industrial automation to monitor, display, and record analog or discrete signals without the need for physical paper charts.
---
## 1. Technical Specifications
The model code `73VR2102-E-R` breaks down into specific hardware configurations.
| Component | Specification | Description |
| :--- | :--- | :--- |
| **Series** | 73VR21xx | Paperless Recording System |
| **Display** | 5.5-inch TFT Color LCD | QVGA (320 x 240) resolution with backlight |
| **Input Channels** | 2 Channels | Universal inputs (DC, Thermocouple, RTD) |
| **Power Supply** | 100 – 240V AC | Standard industrial AC power input |
| **Storage** | CF Card Slot | Used for data logging and configuration backup |
| **Mounting** | Panel Mount | Designed for control cabinet integration |
---
## 2. Key Electronic Features
### Universal Input Circuitry
One of the most significant electronic aspects of this unit is its **Universal Input** design. Each channel is equipped with a high-resolution A/D converter and signal conditioning electronics that allow it to accept:
* **DC Voltage:** Range from $\pm 60mV$ to $\pm 10V$.
* **DC Current:** 4 – 20mA (via external shunt resistor).
* **Thermocouples:** Types K, E, J, T, B, R, S, C, N, and U.
* **RTD:** Pt100, JPt100, Pt50, Ni100, etc.
### Data Management and Communication
* **Sampling Rate:** Typically ranges from 100ms up to several minutes per sample, depending on settings.
* **Isolation:** High-level galvanic isolation between inputs, power, and communication ports to prevent ground loops.
* **Interfaces:** Usually includes an RS-485 port (Modbus RTU) or Ethernet (Modbus TCP) for SCADA integration.
### Storage and Memory
The device uses internal volatile memory for immediate processing and non-volatile flash memory (CF Card) for long-term data archival. This ensures data integrity even during a power failure.
---
## 3. Physical Interface and Layout
The front panel is designed for industrial environments (IP65 rated), while the rear contains the electronic terminal blocks.
* **Front:** Navigation keys (Up, Down, Left, Right, ESC, ENT) and the LCD display.
* **Rear Terminals:**
* **Power:** L, N, and Ground.
* **Inputs:** Screw terminals for signal wiring.
* **Comms:** D-sub or terminal pins for RS-485.
---
## 4. Usage Example (Wiring Configuration)
To wire a standard 4-20mA sensor to this device, you would follow this general electronic logic:
```markdown
1. Install a 250Ω precision shunt resistor across the input terminals.
2. Configure the internal software setting to "1-5V DC" or "4-20mA".
3. Connect the (+) of the sensor to the (+) of the terminal.
4. Connect the (-) of the sensor to the (-) of the terminal.
```
- ⤷
How do I configure the sampling rate for the 73VR2102?
- ⤷ What is the maximum capacity CF card supported by this model?
- ⤷ How do I perform a factory reset on this paperless recorder?