8536SDO2V01S
AI

The **8536SDO2V01S** is a specific model of a NEMA-rated magnetic motor starter manufactured by **Schneider Electric (Square D)**. This device is used to start and stop electric motors while providing thermal overload protection.
Below is a breakdown of its core components and technical specifications.
### 1. Component Breakdown
The part number can be decoded to understand its specific electronic and mechanical makeup:
| Code Segment | Description | Details |
| :--- | :--- | :--- |
| **8536** | Type | NEMA Magnetic Motor Starter |
| **S** | Size | NEMA Size 2 (Rated for higher current/HP) |
| **D** | Enclosure | Open Style (No external metal box/can) |
| **O** | Design | Non-Reversing |
| **2** | Number of Poles | 3-Pole (Typical for 3-phase motors) |
| **V01** | Coil Voltage | 24V AC, 60Hz |
| **S** | Special Feature | Separate Control Circuit (Control power is separate from motor power) |
---
### 2. Key Electronic & Mechanical Parts
#### A. The Magnetic Contactor
The heart of the unit. When the **24V AC (V01)** signal is applied to the electromagnetic coil, it creates a magnetic field that pulls the power contacts shut, allowing electricity to flow to the motor.
#### B. NEMA Size 2 Contacts
These are heavy-duty silver-alloy contacts designed to handle:
* **Continuous Amperage:** Up to 45 Amps.
* **Horsepower (HP):** Approximately 10 HP at 200V or up to 25 HP at 460/575V.
#### C. Thermal Overload Relay (Melting Alloy)
This starter typically utilizes a **Motor Logic** or **Melting Alloy** overload block.
* **Function:** It monitors the current flowing to the motor. If the current stays too high for too long (overload), the heat melts a specialized solder, tripping the mechanism and cutting power to the coil to prevent the motor from burning out.
* *Note: Thermal units (heaters) are usually sold separately based on the specific Full Load Amps (FLA) of your motor.*
#### D. Control Circuit (The "S" Feature)
Because this is the **"S" version**, the control coil is wired for a **Separate Control Source**. This means the 24V used to trigger the starter does not come from the high-voltage lines (L1, L2, L3) powering the motor; it must be provided by an external transformer or PLC.
---
### 3. Technical Specifications Table
| Feature | Specification |
| :--- | :--- |
| **Phase** | 3-Phase |
| **Power Rating** | 45A |
| **Control Voltage** | 24V AC @ 60 Hz / 24V AC @ 50 Hz |
| **Mounting** | Surface / Panel Mount |
| **Overload Type** | Melting Alloy (standard) |
| **Standards** | UL Listed, CSA Certified, NEMA rated |
---
### 4. Wiring Diagram (Simplified Logic)
```mermaid
graph LR
A[24V AC Control Source] --> B(Coil A1)
B --> C(Overload NC Contact)
C --> D(Coil A2 / Common)
L1[Line 1] -- Contact -- M1[Motor T1]
L2[Line 2] -- Contact -- M2[Motor T2]
L3[Line 3] -- Contact -- M3[Motor T3]
```
---
- ⤷What specific heater elements are compatible with the NEMA Size 2 overload block?
- ⤷ How do I wire a 24V PLC output to trigger this starter?
- ⤷ Can this starter be converted to a NEMA 1 enclosure later?