8536SDO2V08
AI

The **8536SDO2V08** is a specific model of a NEMA motor starter manufactured by **Schneider Electric (Square D)**. It is part of the Type S series, designed for controlling AC motors by providing a means for starting, stopping, and protecting the motor.
---
### ## Technical Specifications
| Feature | Specification |
| :--- | :--- |
| **Manufacturer** | Schneider Electric (Square D) |
| **Product Type** | Non-Reversing Magnetic Motor Starter |
| **NEMA Size** | Size 2 |
| **Current Rating** | 45 Amperes |
| **Number of Poles** | 3-Pole |
| **Control Voltage** | 208 V AC @ 60 Hz |
| **Enclosure Type** | Open (No physical box included) |
| **Overload Type** | Melting Alloy (Heater elements sold separately) |
---
### ## Key Electronic & Mechanical Components
#### 1. Magnetic Contactor
The core of the unit is a **3-pole magnetic contactor**. When the 208V control circuit is energized, an electromagnetic coil pulls the power contacts closed, allowing high-voltage electricity to flow to the motor.
#### 2. Control Coil (V08 Code)
The "V08" suffix specifically identifies the **operating voltage** of the electromagnetic coil.
* **Voltage:** 208V AC.
* **Frequency:** 60 Hz.
* This coil must match the control circuit voltage to prevent burning out the component or failing to engage the contacts.
#### 3. Overload Relay Block
This starter uses a **Melting Alloy Overload Relay**. It serves as the "brain" for thermal protection.
* **Thermal Units:** It requires "Thermal Units" (Heaters) to be installed. These are sized specifically to the Full Load Amps (FLA) of the motor.
* **Protection:** If the motor draws too much current, the heater melts a small amount of alloy, tripping the mechanism and disconnecting the coil circuit to save the motor.
#### 4. Auxiliary Contacts
The unit typically includes one **Normally Open (N.O.)** auxiliary contact (often referred to as a "holding circuit" or "seal-in" contact) used for three-wire control logic (Start/Stop buttons).
---
### ## Typical Application Wiring
```mermaid
graph TD
A[L1/L2/L3 Power In] --> B[8536SDO2V08 Starter]
B --> C[Overload Relay]
C --> D[Motor]
E[208V Control Signal] --> F[Coil Terminals A1/A2]
```
---
### ## Maintenance Notes
* **Contact Inspection:** Because this is an open-style NEMA starter, the contacts are robust but should be inspected periodically for pitting or carbon buildup.
* **Heater Selection:** The starter will **not operate** correctly without the proper thermal units installed in the overload block. These must be purchased based on the specific motor nameplate data.
- ⤷
How do I select the correct thermal unit heaters for this starter?
- ⤷ Can this starter be used with a 480V motor if the coil is 208V?
- ⤷ What is the difference between an 'Open' type and a 'NEMA 1' enclosure for this model?