ADR5041AKSZ-R2
AI

The **ADR5041AKSZ-R2** is a high-precision shunt mode voltage reference designed by Analog Devices. It is widely used in space-constrained applications that require a stable voltage output despite fluctuations in temperature or input current.
---
### 1. Key Technical Specifications
The following table highlights the core electrical characteristics of the ADR5041AKSZ-R2:
| Parameter | Specification |
| :--- | :--- |
| **Output Voltage ($V_{out}$)** | 2.500 V |
| **Initial Accuracy** | ±0.1% (Grade A) |
| **Temperature Coefficient** | 100 ppm/°C |
| **Operating Current Range** | 50 µA to 15 mA |
| **Output Noise (0.1 Hz to 10 Hz)** | 125 µV p-p |
| **Package Type** | SC70-3 (KSZ) |
| **Operating Temperature** | -40°C to +125°C |
---
### 2. Functional Description
The device operates as a **Shunt Regulator** (similar to a high-precision Zener diode). It maintains a constant voltage across its terminals by varying the amount of current it shunts to ground.
#### How it works:
1. **Shunt Configuration:** Unlike series references, this device requires an external resistor ($R_{bias}$) placed between the input voltage and the reference pin.
2. **Regulation:** It absorbs more or less current to ensure the voltage drop across the load remains exactly 2.5V.
3. **No Output Capacitor Required:** The ADR5041 is designed to be stable without an external output capacitor, saving board space, though it can handle capacitive loads if necessary.
---
### 3. Pin Configuration (SC70-3)
The SC70 package is extremely small, making it ideal for portable electronics.
| Pin No. | Name | Function |
| :--- | :--- | :--- |
| **1** | **K** | Cathode (Positive Terminal) |
| **2** | **NC** | No Connect (Leave floating) |
| **3** | **A** | Anode (Negative/Ground Terminal) |
---
### 4. Typical Applications
* **Precision Data Acquisition:** Providing a stable reference for ADCs (Analog-to-Digital Converters).
* **Battery-Powered Equipment:** Due to its low minimum operating current (50 µA).
* **Industrial Process Control:** Used in 4-20 mA loops and sensor transmitters.
* **Portable Instrumentation:** Multimeters and handheld testing gear.
---
### 5. Circuit Implementation Example
To use the ADR5041, you must calculate the bias resistor ($R_{S}$) based on your input voltage ($V_{S}$):
```text
Formula: Rs = (Vs - Vout) / (I_load + I_shunt)
Example:
If Vs = 5V, Vout = 2.5V, and desired current is 1mA:
Rs = (5V - 2.5V) / 0.001A = 2500 Ohms (2.5kΩ)
```
- ⤷
How do I calculate the optimal bias resistor for varying input voltages?
- ⤷ What are the main differences between the A-grade and B-grade versions of this chip?