HRS-44-R
AI

The **HRS-44-R** refers to a specific series of **Rotary Dips** or **Rotary Selectors**, commonly manufactured by brands like *Hartmann* (part of the Phoenix Mecano group) or similar electronic component manufacturers.
These components are used to set binary or hexadecimal values manually on a PCB (Printed Circuit Board).
---
## 1. Technical Specifications
The "44" and "R" in the part number typically denote the specific mechanical and electrical configuration of the switch.
| Parameter | Typical Value / Description |
| :--- | :--- |
| **Switch Type** | Rotary Code Switch |
| **Output Code** | BCD (Binary Coded Decimal) or Hexadecimal |
| **Number of Positions** | 10 (0-9) or 16 (0-F) |
| **Mounting Type** | Through-hole (THT) or Surface Mount (SMT) |
| **Actuator Style** | Arrow-shaped slot / Flush or Extended shaft |
| **Contact Rating** | 100mA at 50V DC (Non-switching) / 100mA at 5V DC (Switching) |
---
## 2. Pin Configuration and Logic
The HRS-44-R series is designed to output a digital signal based on the physical position of the rotor.
### Terminal Layout
Usually, these devices have 5 pins:
1. **Common (C):** The input voltage or ground pin.
2. **1 (2^0):** Least Significant Bit (LSB).
3. **2 (2^1):** Second bit.
4. **4 (2^2):** Third bit.
5. **8 (2^3):** Most Significant Bit (MSB).
### Binary Example (Position 7)
If the switch is set to "7", the logic pins will connect to the Common pin as follows:
* Pin 1: **High**
* Pin 2: **High**
* Pin 4: **High**
* Pin 8: **Low**
*(Result: 1+2+4 = 7)*
---
## 3. Key Electronic Features
* **Gold-Plated Contacts:** Ensures low contact resistance and prevents oxidation over long periods of inactivity.
* **Sealed Construction:** Most "R" variants are wash-tight (IP67 rated), meaning they can undergo wave soldering and aqueous cleaning without internal contamination.
* **Detent Mechanism:** Provides a tactile "click" to ensure the switch sits perfectly on the intended value, preventing ambiguous readings between positions.
---
## 4. Common Applications
These parts are rarely interacted with by the end-user. Instead, they are used by technicians for:
* **Address Setting:** Setting the unique ID for a device on a bus (e.g., RS-485 or CAN bus).
* **Mode Selection:** Configuring hardware parameters (like baud rate or operating mode) without needing a screen or software interface.
* **Industrial Controls:** PLCs and motor drives often use these for manual calibration.
---
- ⤷
What is the difference between BCD and Hexadecimal versions of this switch?
- ⤷ How do I wire this switch to an Arduino or Microcontroller?
- ⤷ Can this switch be used for AC power applications?