KTS-R-150
AI

The **KTS-R-150** is a high-performance industrial fuse belonging to the **Limitron™** series, manufactured by Eaton (Bussmann Division). It is specifically designed to provide high-speed current limitation and protection for electrical circuits.
---
## 1. Technical Specifications
The following table summarizes the primary electrical characteristics of the KTS-R-150:
| Feature | Specification |
| :--- | :--- |
| **Current Rating** | 150 Amperes |
| **Voltage Rating (AC)** | 600 Vac |
| **Interrupting Rating** | 200,000 Amps (RMS Symmetrical) |
| **Fuse Class** | Class RK1 |
| **Time Characteristics** | Fast-Acting |
| **Material** | Melamine glass tube with plated end caps |
---
## 2. Key Features and Construction
The KTS-R-150 is engineered for environments where sensitive equipment requires immediate protection against short circuits.
* **Current Limitation:** As a Class RK1 fuse, it provides a high degree of current limitation. It reacts significantly faster than standard Class RK5 fuses, reducing the "let-through" energy during a fault.
* **Rejection Feature:** The "R" in the part number indicates it is a rejection-style fuse. When used with a Class R fuse block, the physical dimensions prevent the accidental installation of lower-rated fuses (like Class H or K).
* **Internal Link:** Uses a specialized fast-melting element designed to clear faults in less than 0.008 seconds (half a cycle) under high fault conditions.
---
## 3. Common Applications
The KTS-R-150 is typically found in the following electronic and electrical systems:
1. **Branch Circuit Protection:** Used in main power distribution panels to protect downstream components.
2. **Motor Controllers:** Ideal for protecting non-inductive loads or as backup protection for motor circuits where high-speed clearing is required.
3. **UPS Systems:** Protecting the rectifiers and inverters in Uninterruptible Power Supplies.
4. **Resistive Loads:** Excellent for electric heating systems and lighting circuits.
---
## 4. Part Number Breakdown
Understanding the nomenclature helps in identifying the specific protection level:
| Prefix | Series/Voltage | Amperage |
| :--- | :--- | :--- |
| **KTS** | 600V Limitron Series | - |
| **-R** | Rejection Class RK1 | - |
| **-150** | - | 150 Amp Rating |
---
- ⤷
What is the difference between KTS-R and KTN-R fuses?
- ⤷ Can a KTS-R-150 fuse be used in a standard Class H fuse holder?
- ⤷ What are the specific 'let-through' current values for this fuse at 200kA?