The **KTS-R-20** is a specific model of high-performance industrial fuse. It belongs to the **Limitron™** series manufactured by Bussmann (now part of Eaton). Below is a detailed breakdown of its electronic specifications and characteristics.
---
### 1. Technical Specifications
The KTS-R-20 is a Class RK1 fuse, which means it offers a high degree of current limitation and safety for sensitive electronic circuits.
| Feature | Specification |
| :--- | :--- |
| **Model Number** | KTS-R-20 |
| **Current Rating** | 20 Amperes |
| **Voltage Rating (AC)** | 600 Vac |
| **Interrupting Rating** | 200,000 Amps RMS Symmetrical |
| **Fuse Class** | Class RK1 |
| **Response Characteristic** | Fast-Acting |
| **Material** | Melamine tube with silver-plated brass end caps |
---
### 2. Key Electronic Characteristics
* **Fast-Acting Response:** Unlike "Time-Delay" fuses (which allow for temporary surges like motor startups), the KTS-R-20 is designed to open very quickly when it detects an overcurrent. This is critical for protecting sensitive semiconductor components.
* **Current Limitation:** It is a "Current Limiting" fuse. In the event of a short circuit, it reacts so quickly that it prevents the fault current from reaching its maximum peak, significantly reducing the potential for "Arc Flash" or thermal damage to downstream components.
* **High Interrupting Capacity:** It can safely handle up to 200,000 amps of fault current. This makes it suitable for use in industrial service entrances or heavy-duty control panels where massive energy spikes could occur.
---
### 3. Physical Construction
The part is physically designed to ensure safety and prevent incorrect installation:
1. **Rejection Feature:** The "R" in KTS-R indicates it has a rejection notch. This prevents the installation of lower-rated fuses (like Class H) into the same fuse holder, ensuring the circuit remains protected at the specified RK1 safety level.
2. **Dimensions:** Typically measures approximately **5 inches in length** and **0.81 inches in diameter**, fitting standard 600V, 30A fuse clips (though rated for 20A).
---
### 4. Common Applications
Due to its fast-acting nature and high voltage rating, the KTS-R-20 is primarily used in:
* **Branch Circuit Protection:** Standard industrial power distribution.
* **Non-Inductive Loads:** Resistance heaters and lighting circuits where no high-inrush startup current exists.
* **Semiconductor Protection:** Protecting rectifiers or SCRs (Silicon Controlled Rectifiers) that require immediate disconnection during a fault.
- ⤷