KTS-R-3
AI

### KTS-R-3 Fuse Specifications and Technical Overview
The **KTS-R-3** is a high-performance industrial fuse manufactured by **Bussmann (Eaton)**. It belongs to the **Limitron™** series and is categorized as a **Class RK1** fuse. These fuses are designed for high-speed response to short circuits and provide excellent current limitation.
---
### 1. Key Technical Specifications
The table below outlines the primary electrical characteristics of the KTS-R-3:
| Feature | Specification |
| :--- | :--- |
| **Part Number** | KTS-R-3 |
| **Amperage Rating** | 3 Amps |
| **Voltage Rating (AC)** | 600 Vac |
| **Interrupting Rating** | 200,000 Amps (RMS Symmetrical) |
| **Fuse Class** | Class RK1 |
| **Response Characteristic** | Fast-Acting |
| **Body Material** | Melamine (Fiberglass) tube with plated end caps |
---
### 2. Physical Dimensions
The KTS-R-3 follows the standard physical sizing for 600V, 0-30A Class R fuses to ensure compatibility with standard fuse blocks and disconnect switches.
* **Length:** 5.0 inches (127 mm)
* **Diameter:** 0.81 inches (20.6 mm)
---
### 3. Electronic Features & Benefits
* **Current Limitation:** As a Class RK1 fuse, the KTS-R-3 is significantly more current-limiting than standard Class RK5 fuses. This helps protect sensitive downstream components by stopping a fault before it reaches its peak magnitude.
* **Rejection Feature:** The "R" in KTS-R indicates a rejection notch in the blade/end cap. This prevents the installation of lower-rated fuses (like Class H or K) into a Class R fuse holder, ensuring the safety integrity of the circuit.
* **High Interrupting Rating:** With a 200kA rating, it can safely clear high-energy faults common in industrial power distribution systems.
* **Fast-Acting Response:** Unlike "Time-Delay" fuses, the KTS-R-3 reacts almost instantaneously to overloads. This makes it ideal for resistive loads or circuits without high inrush currents.
---
### 4. Typical Applications
The KTS-R-3 is commonly used in the following environments:
1. **Branch Circuit Protection:** Providing localized protection for individual circuits.
2. **Control Transformers:** Protecting the primary side of small transformers.
3. **Lighting Circuits:** Used in non-inductive lighting loads where fast clearing is required.
4. **Panelboards:** General-purpose protection in industrial power panels.
- ⤷
What is the difference between KTS-R (RK1) and FRS-R (RK5) fuses?
- ⤷ Can a KTS-R-3 fuse be used in a 240V circuit?
- ⤷ What type of fuse holder is required for a Class R rejection fuse?