The **M2AC-AZB-R** is a specific electronic component within the **M2 series** of signal conditioners manufactured by **M-System** (now part of MG CO., LTD). It is a plug-in type signal conditioner designed to accept an AC voltage input and convert it into a standard DC output.
---
### 1. Part Number Breakdown
To understand the electronic capabilities, we must decode the suffix codes:
| Code Segment | Meaning | Specification |
|:---|:---|:---|
| **M2AC** | Model Series | AC Transmitter (Average sensing, RMS calibrated) |
| **-A** | Input Range | 0 – 100V AC |
| **-Z** | Output Range | Special Output (Custom/Non-standard) or Specified range |
| **-B** | Power Input | 100V AC |
| **-R** | Options | Standard RoHS compliant/Specific housing details |
---
### 2. Key Technical Specifications
The device acts as an interface between high-voltage power monitoring and low-voltage control systems (like a PLC or SCADA).
* **Input Frequency:** 50 or 60 Hz.
* **Accuracy:** ±0.3% of span.
* **Response Time:** Approx. 0.5 seconds (0 – 90%).
* **Isolation:** 4-way isolation (Input to Output to Power to Ground).
* **Dielectric Strength:** 2000V AC @ 1 minute.
* **Housing Material:** Flame-resistant resin (Black).
---
### 3. Electronic Architecture
The internal circuitry typically consists of three primary stages:
#### A. Input Conditioning (The "Front End")
The AC voltage (0-100V) enters through a step-down transformer or a precision resistor network. Since it is an **average-sensing** model, it rectifies the AC signal and filters it to find the average value, which is then scaled to represent the RMS value of a sine wave.
#### B. Isolation Barrier
To protect the sensitive DC side from high-voltage transients on the AC side, the device uses **Optical Isolation** or **Transformer Isolation**. This prevents ground loops and ensures safety for the connected PLC/Controller.
#### C. Output Scaling (The "Back End")
The DC signal is amplified and converted into the specific "Z" range (which is often a customized voltage or current signal, e.g., 0-5V or 4-20mA).
---
### 4. Connection Diagram (Simplified)
Below is a typical pin-out representation for the M2 series base:
| Pin No. | Function | Description |
|:---:|:---|:---|
| 1 | Output (+) | Positive DC Signal |
| 2 | Output (-) | Negative DC Signal |
| 4 | Power (U) | 100V AC Power Supply |
| 5 | Power (V) | 100V AC Power Supply |
| 7 | Input (U) | AC Voltage Input (+) |
| 8 | Input (V) | AC Voltage Input (-) |
---
- ⤷