M2PHS2L-15A-R
AI

The **M2PHS2L-15A-R** is a specific model of a **Miniature Circuit Breaker (MCB)** or a specialized power switch, typically part of a modular series used in industrial control panels or power distribution units (PDUs).
Below is a breakdown of its electronic and mechanical specifications:
### 1. Component Overview
The part belongs to a class of protection devices designed to safeguard circuits from overcurrent and short circuits.
| Feature | Specification |
| :--- | :--- |
| **Type** | Magnetic-Hydraulic Circuit Breaker |
| **Current Rating** | 15 Amperes |
| **Number of Poles** | 2-Pole (Switches both Live and Neutral/Phase) |
| **Mounting Type** | Panel Mount or Plug-in (Model dependent) |
| **Safety Standard** | Usually UL/CSA/TUV compliant |
---
### 2. Key Electronic Features
#### A. Magnetic-Hydraulic Tripping Mechanism
Unlike thermal breakers that rely on heat and ambient temperature, this part uses a **Solenoid (Magnetic coil)** and a **Hydraulic dampener**.
* **Precision:** It is not affected by changes in the surrounding temperature (ambient heat).
* **Time Delay:** The hydraulic fluid controls the "trip curve," allowing for brief surges (like motor startups) without tripping, while shutting down instantly during a dead short.
#### B. 2-Pole Configuration (2L)
The "2L" designation indicates two linked poles. This ensures that if a fault occurs on one line, both lines are disconnected simultaneously, ensuring the downstream equipment is completely isolated from power.
#### C. Contact Material
The internal contacts are typically made of **Silver Alloy**. This provides:
* Low electrical resistance.
* Resistance to "welding" during high-current arcing.
---
### 3. Technical Specifications Table
| Parameter | Value (Typical) |
| :--- | :--- |
| **Rated Voltage** | 250V AC / 50V-80V DC |
| **Interrupting Capacity** | 1,000A - 5,000A (Model specific) |
| **Operating Temp** | -40°C to +85°C |
| **Dielectric Strength** | 1,500V 50/60Hz |
| **Termination** | Screw Terminals or Quick-Connect Tabs |
---
### 4. Application Areas
* **Telecommunications:** Protecting sensitive DC power racks.
* **Industrial Automation:** Control circuits for PLCs and sensors.
* **Medical Equipment:** High-precision power protection where temperature stability is critical.
* **Marine Electronics:** Reliable switching in environments with fluctuating temperatures.
---
- ⤷
What is the difference between a thermal breaker and this magnetic-hydraulic model?
- ⤷ Can the M2PHS2L-15A-R be used for DC applications?
- ⤷ How do I interpret the '15A' rating regarding continuous vs. peak load?