METSECT5MB030
AI

The **METSECT5MB030** is a specific model within the Schneider Electric **PowerLogic** range. It is a low-voltage **Current Transformer (CT)** designed for use with metering and monitoring equipment.
---
### 1. Key Technical Specifications
Below are the primary electrical and physical characteristics of the METSECT5MB030:
| Feature | Specification |
| :--- | :--- |
| **Product Type** | Current Transformer (Tropicalized) |
| **Current Ratio** | 300 / 5 A |
| **Accuracy Class** | Class 0.5 at 6 VA / Class 1 at 8 VA |
| **Mounting Mode** | By screws, clips, or DIN rail |
| **Primary Current** | 300 A |
| **Secondary Current** | 5 A |
| **Safety Factor** | < 5 |
| **Insulation Voltage** | 3 kV |
---
### 2. Electronic Components and Construction
While a current transformer does not contain complex microchips, its "electronic" operation relies on precise electromagnetic induction components:
* **Secondary Terminals:** These are the output points (S1 and S2) where the 5A signal is sent to the meter. They usually feature screw-clamp terminals for secure connection.
* **Toroidal Core:** A high-permeability magnetic core that ensures linear transformation of the current and minimizes energy loss (hysteresis).
* **Encapsulation:** The internal windings are protected by a flame-retardant (UL94V-0) plastic housing, ensuring the device can withstand industrial environments.
* **Sealable Covers:** The METSECT5MB030 includes integrated covers for the secondary terminals to prevent unauthorized tampering, which is critical for billing/revenue applications.
---
### 3. Application and Usage
The METSECT5MB030 is used to "step down" a high current (up to 300A) to a lower, manageable current (5A) that electronic power meters can safely process.
1. **Measurement:** Used with PowerLogic power meters to monitor energy consumption.
2. **Protection:** Provides input for relays to detect overcurrent conditions.
3. **Integration:** Common in Low Voltage (LV) switchboards and motor control centers.
---
### 4. Safety Warning
> **CRITICAL:** Never leave the secondary terminals (S1, S2) of a current transformer open-circuited while the primary current is flowing. This can lead to extremely high voltage buildup, causing insulation failure, equipment damage, or fatal electric shock.
- ⤷
How do I determine if Class 0.5 or Class 1 accuracy is needed for my application?
- ⤷ What is the maximum cable diameter that can pass through the METSECT5MB030?
- ⤷ What is the difference between a tropicalized CT and a standard CT?