Motore di ricerca datesheet componenti elettronici
  Italian  ▼
ALLDATASHEETIT.COM

X  

  • MVT-252

  • AI
    The **MVT-252** is a high-precision, digital vacuum transducer (often associated with brands like INFICON or similar industrial vacuum gauge manufacturers). It is designed to measure pressure in the medium to high vacuum range. Below is an explanation of its electronic components and technical architecture. --- ### 1. Key Electronic Components | Component | Function | | :--- | :--- | | **Sensing Element** | Usually a Pirani-style heated filament or a piezo-resistive bridge that changes resistance based on gas thermal conductivity. | | **A/D Converter** | Converts the analog voltage signals from the sensor into a 24-bit digital signal for high resolution. | | **Microprocessor** | Processes calibration data, linearizes the signal, and manages communication protocols. | | **EEPROM Storage** | Stores factory calibration constants and user-defined setpoints. | | **Signal Interface** | RS-232, RS-485, or EtherCAT hardware for digital communication with a PLC or PC. | --- ### 2. Operational Circuitry The device operates on a **Constant Temperature Principle**. The electronics maintain the sensing filament at a constant temperature above the ambient environment. 1. **Bridge Circuit:** A Wheatstone bridge is typically used to monitor the resistance of the filament. 2. **Feedback Loop:** As gas molecules hit the filament and carry heat away, the electronics increase the current to keep the temperature steady. 3. **Measurement:** The electrical power required to maintain this temperature is proportional to the gas pressure. --- ### 3. Technical Specifications (Electronic View) | Parameter | Typical Value / Description | | :--- | :--- | | **Supply Voltage** | +15 to +30 VDC | | **Power Consumption** | < 2 Watts (Standard operation) | | **Output Signal** | 0 to +10 VDC (Analog) or Digital (RS-232/485) | | **Measurement Range** | $1 \times 10^{-4}$ mbar to $1000$ mbar | | **Connector Type** | D-Sub 9-pin or 15-pin (Standard industrial pinout) | --- ### 4. Interface and Connectivity The electronics are shielded against Electromagnetic Interference (EMI) to ensure accuracy in industrial environments where motors or pumps might generate noise. * **Setpoints:** The MVT-252 usually includes two independent dry contact relays (Solid State) that can be programmed to trigger at specific pressure levels. * **Status LED:** Integrated LEDs provide visual feedback on the health of the electronics (Green = OK, Red = Error/Filament Burnout).
    ✨ Follow-up Questions
    • ⤷ How do you calibrate the MVT-252 electronic offset?
    • ⤷ What are the specific pinout diagrams for the D-Sub connector?
    • ⤷ Can the MVT-252 be used with corrosive gases?