VIPER50
AI

The **VIPER50** is a high-performance, offline switched-mode power supply (SMPS) primary switcher. Manufactured by STMicroelectronics, it integrates a dedicated current-mode PWM controller with a high-voltage Power MOSFET on the same silicon chip.
---
## 1. Internal Functional Components
The VIPER50 is complex because it combines low-voltage control logic with high-voltage power handling.
| Component | Function |
| :--- | :--- |
| **Power MOSFET** | Handles high voltage (typically up to 700V) and switches the primary current. |
| **PWM Controller** | Regulates the duty cycle based on feedback to maintain output voltage. |
| **Current Sense** | Monitors the drain current for protection and control. |
| **Startup Circuit** | High-voltage current source that charges the VDD capacitor during power-up. |
| **Error Amplifier** | Compares feedback to an internal reference (usually 13V on VDD). |
---
## 2. Pinout Configuration
The device is typically found in **TO-220** or **Pentawatt** packages.
1. **DRAIN**: Connected to the internal MOSFET drain; attaches to the primary winding of the transformer.
2. **SOURCE**: Ground reference for the control circuits and the MOSFET source.
3. **VDD**: Supply voltage for the control logic (usually requires an external capacitor).
4. **COMP**: Input for the feedback loop (compensation) to adjust the PWM duty cycle.
5. **OSC**: Pin to connect an external RC network to set the switching frequency.
---
## 3. Key Technical Specifications
Below are the critical electrical parameters for the VIPER50:
| Parameter | Value |
| :--- | :--- |
| **Drain-Source Voltage ($V_{dss}$)** | 700V |
| **Max Switching Frequency** | Up to 200 kHz |
| **Output Power Range** | ~50W (Wide range) / ~100W (European range) |
| **Feedback Reference** | 13V |
| **Operating Supply Voltage** | 8V to 15V |
---
## 4. Protection Features
The VIPER50 is designed to be "rugged," meaning it includes several autonomous safety features:
* **Over-Temperature Protection (OTP):** The device shuts down if the junction temperature exceeds $150^\circ C$.
* **Over-Current Protection (OCP):** Limits the peak current through the MOSFET to prevent transformer saturation.
* **Under-Voltage Lockout (UVLO):** Prevents the device from operating if $V_{DD}$ is too low to drive the MOSFET gate effectively.
* **Burst Mode:** Under light load conditions, it enters a low-power mode to improve efficiency and reduce "standby" consumption.
---
## 5. Basic Application Circuit Example
To use a VIPER50, you typically need the following external components:
```c
[AC Input] -> [Bridge Rectifier] -> [Bulk Capacitor] -> [Transformer Primary]
|
[VIPER50 DRAIN Pin]
|
[Auxiliary Winding] -> [Diode/Capacitor] -> [VIPER50 VDD Pin]
```
---
- ⤷
What are the main differences between the VIPER50 and VIPER22A?
- ⤷ How do you calculate the RC values for the OSC pin frequency?
- ⤷ What type of transformer is best suited for a VIPER50 design?