W2SP-114-R/UL
AI

The **W2SP-114-R/UL** is a specialized power entry module or surge protection component, typically associated with industrial or commercial electrical systems. Below is a detailed breakdown of its electronic characteristics and specifications.
---
## 1. Component Overview
This device is designed primarily as a **Surge Protective Device (SPD)** or a high-quality power connection interface that meets specific safety standards (UL). It is engineered to protect sensitive electronic equipment from voltage spikes and transients.
### Key Specifications Table
| Feature | Specification Details |
| :--- | :--- |
| **Model Number** | W2SP-114-R/UL |
| **Type** | Surge Protective Device / Power Entry |
| **Safety Certification** | UL Listed (Underwriters Laboratories) |
| **Protection Mode** | Line-to-Neutral, Line-to-Ground |
| **Mounting Style** | Panel Mount or DIN-rail (depending on specific housing) |
| **Application** | Industrial Control Panels, Telecommunications |
---
## 2. Electronic Characteristics
### A. Surge Suppression
The unit utilizes Internal **Metal Oxide Varistors (MOVs)** or Gas Discharge Tubes (GDTs) to clamp excess voltage. When a surge occurs, the resistance of these components drops rapidly, shunting the excess current to the ground and protecting downstream circuits.
### B. "R" Designation (Remote Signaling)
The "R" in the part number usually indicates a **Remote Relay Contact**.
* **Function:** It provides a dry contact signal to a PLC or monitoring system.
* **Purpose:** If the internal protection fails (due to a massive surge), the relay changes state to alert maintenance personnel that the module needs replacement.
### C. UL Listing Significance
The `/UL` suffix confirms that the part complies with **UL 1449** (Standard for Surge Protective Devices). This ensures:
1. **Thermal Protection:** The device will safely disconnect itself from the power source if it overheats.
2. **Short Circuit Current Rating (SCCR):** It can withstand specific fault levels without exploding or creating a fire hazard.
---
## 3. Typical Wiring Configuration
The device generally follows a standard 3-wire or 4-wire installation pattern:
```text
L (Line) --------> [ W2SP-114-R/UL ] --------> Protected Load
N (Neutral) --------> [ W2SP-114-R/UL ] --------> Protected Load
G (Ground) --------> [ W2SP-114-R/UL ]
Relay Terminals (Common, NC, NO) -> To Monitoring System
```
---
## 4. Applications
* **Automation:** Protecting PLC power supplies from motor switching noise.
* **IT Infrastructure:** Guarding servers against lightning-induced surges.
* **Medical Equipment:** Ensuring stable power delivery in sensitive diagnostic tools.
- ⤷
What is the maximum discharge current (Imax) for the W2SP series?
- ⤷ How do I wire the remote status relay to a PLC?
- ⤷ What is the difference between the 'R' and non-'R' versions of this part?