W2VABS-3WDA-R2
AI

Based on the provided part number **W2VABS-3WDA-R2**, this component belongs to the **industrial automation and safety sensor** category, specifically manufactured by **Wenglor Sensoric**.
Below is a detailed breakdown of its electronic characteristics and technical specifications.
---
## 1. Component Overview
The W2VABS-3WDA-R2 is a **Safety Bolt** designed for use in safety-locking systems. It typically works in conjunction with non-contact safety switches (like the RSS series or specific RFID-coded sensors) to secure protective doors in industrial environments.
### Technical Specifications Table
| Feature | Specification |
| :--- | :--- |
| **Manufacturer** | Wenglor Sensoric |
| **Part Type** | Safety Bolt / Mechanical Lock Housing |
| **Compatibility** | Optimized for RFID Safety Switches |
| **Locking Force** | High mechanical retention (up to 1150 N depending on assembly) |
| **Operating Temperature** | -25°C to +70°C |
| **Material** | Stainless Steel / High-grade Plastic (Zinc Die-Cast options available) |
| **Protection Rating** | IP67 / IP69K (when fully assembled) |
---
## 2. Key Electronic & Mechanical Features
### A. RFID Integration
While the bolt itself is a mechanical housing, the **"WDA"** designation often implies compatibility with RFID-coded electronics.
* **Tamper Protection:** It integrates with sensors that use uniquely coded actuators to prevent bypassing.
* **Status Indication:** Usually includes windows or mounts for LED status indicators on the mated sensor.
### B. Safety Performance
When paired with the correct safety relay or controller, this part contributes to high-level safety circuits:
* **Performance Level (PL):** Can reach **PLe** (Category 4) according to EN ISO 13849-1.
* **SIL Rating:** Suitable for **SIL 3** applications (IEC 61508).
### C. Manual Release & Logic
The "R2" suffix typically denotes a specific revision or a version equipped with a **mechanical emergency release**. This allows the electronic lock to be bypassed manually from the inside or outside in case of a power failure or emergency situation.
---
## 3. Wiring and Integration
The electronic interface is handled by the internal sensor (e.g., an RSSD or similar Wenglor sensor). The wiring standard is usually:
```yaml
Pin Layout (M12 8-Pin Typical):
1: A1 (24V DC Supply)
2: X1 (Safety Input 1)
3: OS1 (Safety Output 1)
4: X2 (Safety Input 2)
5: OS2 (Safety Output 2)
6: OUT (Diagnostic Output)
7: A2 (0V / GND)
8: IN (Locking/Unlocking Signal)
```
---
- ⤷What specific Wenglor safety sensors are compatible with this bolt model?