State-of-the-Art EPIC-IIBE BiCMOS Design
Significantly Reduces Power Dissipation
ESD Protection Exceeds 2000 V Per
MIL-STD-883, Method 3015; Exceeds 200 V
Using Machine Model (C = 200 pF, R = 0)
Latch-Up Performance Exceeds 500 mA Per
JEDEC Standard JESD-17
Typical VOLP (Output Ground Bounce) < 1 V
at VCC = 5 V, TA = 25°C
High-Drive Outputs (–32-mA IOH,
64-mA IOL)
Parity Error Flag With Parity
Generator/Checker
Register for Storage of the Parity Error Flag
Package Options Include Plastic
Small-Outline (DW) Packages, Ceramic
Chip Carriers (FK), and Plastic (NT) and
Ceramic (JT) DIPs
description
The ’ABT833 8-bit to 9-bit parity transceivers are
designed for communication between data buses.
When data is transmitted from the A bus to the
B bus, a parity bit is generated. When data is
transmitted from the B bus to the A bus with its
corresponding parity bit, the open-collector
parity-error (ERR) output indicates whether or not
an error in the B data has occurred. The
output-enable (OEA and OEB) inputs can be used
to disable the device so that the buses are
effectively isolated. The ’ABT833 provide true
data at their outputs.
A 9-bit parity generator/checker generates a
parity-odd (PARITY) output and monitors the
parity of the I/O ports with the ERR flag. ERR is
clocked into the register on the rising edge of the
clock (CLK) input. The error flag register is cleared
with a low pulse on the clear (CLR) input. When
both OEA and OEB are low, data is transferred
from the A bus to the B bus and inverted parity is
generated. Inverted parity is a forced error
condition that gives the designer more system
diagnostic capability.
|