| Motore di ricerca datesheet componenti elettronici |
|
MP174GS Scheda tecnica(PDF) 12 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP174GS Scheda tecnica(HTML) 12 Page - Monolithic Power Systems |
|
12 / 22 page ![]() MP174 – NON-ISOLATED OFF-LINE REGULATOR MP174 Rev. 1.01 www.MonolithicPower.com 12 8/18/2016 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2016 MPS. All Rights Reserved. R1 R2 Vo 2.55V R2 Frequency Foldback and Peak Current Compression The MP174 remains highly efficient under light- load condition by reducing the switching frequency automatically. Under light-load or no-load conditions, the output voltage drops very slowly, which increasing the MOSFET off time. Thus the frequency decreases as the load decreases. Determine the switching frequency as: in o o s peak o in (V V ) V f 2L(I I ) V , for CCM in O o o s 2 peak in 2(V V ) I V f LI V , for DCM At the same time, the peak current limit decreases from 660mA as the off-time increases. In standby mode, the frequency and the peak current are both minimized, allowing for a smaller dummy load. As a result, peak-current compression helps further reduce no-load consumption. Peak current limit can be estimated from the following equation ( τoff is the power module’s off time): Peak off I 660mA (2.4mA / s) ( 12 s) EA Compensation - + VFB M - + V ref 2.55V EA - + FB Comparator Vramp Vramp Ipeak + + Figure 4: EA and Ramp Compensation MP174 has internal error amplifier (EA) compensation loop. It samples the feedback voltage 6us after the MOSFET turns off, and regulates the output based on the 2.55V reference voltage. Ramp Compensation An internal ramp compensation circuit improves the load regulation. As shown in Figure 4, an exponential voltage signal added to pull down the reference voltage of the feedback comparator. The ramp compensation is a function of the load conditions: the compensation is about the 1mV/µs under full-load conditions compensation increases exponentially as the peak current decreases. Over-Load Protection (OLP) Maximum output power of MP174 is limited by maximum switching frequency and peak current limit. If the load current is too large, output voltage drops, so that the FB voltage drops. When the FB voltage drops below 1.7V it is considered as an error flag and timer starts. If the timer reaches 220ms (fS=28kHz), OLP occurs. This timer duration avoids triggering OLP when the power supply starts up or load transition. The power supply should start up in less than 220ms (fS=28kHz). The OLP delay time is calculated as per the following equation: Delay 28kHz 220ms fs Short-Circuit Protection (SCP) The MP174 monitors the peak current, and shuts down when the peak current rises above SCP threshold through short-circuit protection. The power supply resumes operation with the removal of the fault. Thermal Shutdown (OTP) To prevent any thermal induced damage, the MP174 shuts down switching when the junction temperature exceeds 150°C. During the thermal shutdown (OTP), the VCC capacitor is discharged to 2.4V, and then the internal high voltage regulator re-charges. MP174 recovers when junction temperature drops below 120°C. |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |