| Motore di ricerca datesheet componenti elettronici |
|
AGL83440C Scheda tecnica(PDF) 4 Page - Agilent(Hewlett-Packard) |
|
|
|||||||||||||||||||||||||||||
AGL83440C Scheda tecnica(HTML) 4 Page - Agilent(Hewlett-Packard) |
|
4 / 8 page ![]() 4 Time Domain Frequency Domain Conversion Gain1,4 (min into 50 Ω load) DC Responsivity1,4 (min) 1300 nm: 20 V/W 1550 nm: 15 V/W 1300 nm 1550 nm 0.3 A/W 0.3 A/W –8 dB2 –10.5 dB2 Pulse Width4,10,14 (calculated:FWHM=0.44/BWopt≈0.312/BWel) Bandwidth4,12,14 < 13 ps FWHM6 dc to 30 GHz nominal (-3dB optical) Rise/Fall Time7,10 (10-90%) <16 ps (calculated) System Aberrations4,13 (response to 2 ps FWHM pulse) 20% peak-to-peak max, <12% typical Noise5,11 Noise Equivalent Power5,11 8.1 µW RMS max, equivalent optical noise power < 18 pW/ √Hz typical Dark Current11 20 nA max, 4 nA typical Maximum Safe Input Optical Power 10 mW (Peak) +10 dBm (Peak) Maximum Operating Input Optical Power (Compression Point) 2 mW (Peak) +3 dBm (Peak) See saturation chart for pulsed power characteristics Input Optical Reflection8 Input Optical Return Loss8 (HMS-10 optical connector) (HMS-10 optical connector) 0.10 % (1250-1600 nm) >30 dB (1250-1600 nm) Wavelength Spectral Response4 1000 nm - 1600 nm Typical Response Curves See Notes, page 7 0 850 1000 1300 1550 83440D Responsivity vs Wavelength Wavelength (nm) 0.1 0.2 0.3 0.4 0.5 FWHM 14.7 ps 0 –50 83440D Uncorrected System Pulse Response 50 0 .5 1 Time (ps) Response of a Agilent 83440D lightwave detector on an Agilent 54124 oscilloscope due to a 2 ps pulsed YAG laser. 100 13 0 –5 –10 0 10 20 30 Frequency (GHz) –3 dB –3 dB opt elec 83440D Frequency Response Deconvolved frequency response from 2 ps pulsed YAG laser measured by Agilent 83440D and Agilent 54124 oscilloscope. 40 –1 –2 –3 0 –5 –4 Typical 83440D Saturation Characteristics 1 0.5 0 0 200 400 Peak Optical Power (mW) 5 ps pulse width (1060 nm) Specifications describe the instrument’s warranted performance over the temperature range 0 to 55°C (except where noted). Supplemental Characteristics are intended to provide information useful in applying the instrument by giving typical but non-warranted performance parameters. These are denoted as “typical,” “nominal,” or “approximate.” Agilent 83440D Specifications and Characteristics |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |