2 / 5 page ![]() Specifications Supply Voltage and Current 12 V dc to 30 V dc; or 24 V ac (± 3 V ac) at 50 Hz to 60 Hz Standard Audible Alarm: 25 mA maximum current Sealed Audible Alarm: 35 mA maximum current Omni-Directional Sealed Audible Alarm: 45 mA maximum current Audible Alarm Standard Audible Alarm: 2.7 kHz ± 500 Hz oscillation frequency; maximum intensity 92 dB at 1 m (3.3 ft) (typical) Sealed Audible Alarm: 2.9 kHz ± 250 Hz oscillation frequency; maximum intensity 94 dB at 1m (3.3 ft) (typical) Omni-Directional Sealed Audible Alarm: 2.1 kHz ± 250 Hz oscillation frequency; maximum intensity 99 dB at 1 m (3.3 ft) (typical) Audible Adjustment Standard Audible Alarm: Unscrew the cover (up to 1.5 turns maximum) to adjust the audible intensity (do not exceed 1.5 turns or the cover may detach during operation). For maximum intensity, rotate the center plug 180° counterclockwise to remove it. Sealed Audible Alarm and Omni-Directional Sealed Audible Alarm with Intensity Adjustment: Rotate the front cover until the desired intensity is reached. Typical Reduction in Sound Intensity with Audible Adjustment (maximum to minimum): • Standard Audible Alarm: 30 dB • Sealed Audible Alarm: 20 dB • Omni-Directional Sealed Audible Alarm: 12 dB Connections Integral 4-pin M12/Euro-style quick disconnect, 150 mm (6 in) PVC cable with a M12/ Euro-style quick disconnect, or 2 m (6.5 ft) integral PVC cable, depending on model Models with a quick disconnect require a mating cordset Vibration and Mechanical Shock Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 1.0 mm amplitude, 5 minutes sweep, 30 minutes dwell) Meets IEC 60068-2-27 requirements (Shock: 30G 11 ms duration, half sine wave) Operating Conditions –20 °C to +50 °C (–4 °F to +122 °F) 95% at +50 °C maximum relative humidity (non-condensing) Environmental Rating UL Type 4X Indoor and UL Type 13 Standard models: IEC IP50 Sealed models: IEC IP67 Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. Supply Wiring (AWG) Required Overcurrent Protection (Amps) 20 5.0 22 3.0 24 2.0 26 1.0 28 0.8 30 0.5 Certifications Dimensions Standard Audible Models 26.9 [1.06] 1/2-14 NPSM 45 [1.77] ø50 [1.97] 111 [4.37] 19 [0.75] M30 X 1.5-6 g 2 ▲ Sealed Audible Models 19 [0.75] M30 X 1.5-6 g 93.4 [3.68] ø45 [1.77] 1/2-14 NPSM ø50 [1.97] Omni-Directional Models ø50 [1.97] 107.5 [4.23] 19.0 [0.75] M30 X 1.5 M12 X 1-6 g 45.0 [1.77] 1/2-14 NPSM All measurements are listed in millimeters [inches], unless noted otherwise. TL50A Audible Indicators 2 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 155019 Rev. J |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |