| Motore di ricerca datesheet componenti elettronici |
|
ZPHS01B Scheda tecnica(PDF) 6 Page - Zhengzhou Winsen Electronics Technology Co., Ltd. |
|
|
|||||||||||||||||||||||||||||
ZPHS01B Scheda tecnica(HTML) 6 Page - Zhengzhou Winsen Electronics Technology Co., Ltd. |
|
6 / 7 page ![]() Zhengzhou Winsen Electronics Technology Co., Ltd www.winsen-sensor.com Tel: 86-371-67169097/67169670 Fax: 86-371-60932988 Email: sales@winsensor.com Leading gas sensing solutions supplier in China! 0x9A 0x00 0x02 0xFD 0x00 0x28 0x00 0x28 0x00 Byte18 Byte19 Byte20 Byte21 Byte22 Byte23 Byte24 Byte25 CO O3 NO2 Reserved Reserved Check sum 0x05 0x00 0x20 0x00 0x50 0x00 0x00 0xEA Note: Item Unit Concentration PM1.0 Ug/m3 (Byte2*256+Byte3)ug/m3= 101ug/m3 PM2.5 Ug/m3 (Byte4*256+Byte5)ug/m3= 54ug/m3 PM10 Ug/m3 (Byte6*256+Byte7)ug/m3= 150ug/m3 CO2 ppm (Byte8*256+Byte9)ppm=410ppm VOC 0~3 grade Temperature 0.1℃ ((Byte11*256+Byte12)-500)*0.1℃=26.5℃ For example: byte11=0x01, byte12=0x59 ((Byte11*256+Byte12)-500)*0.1℃=-15.5℃ Humidity %RH (Byte13*256+Byte14)%RH=40%RH CH2O 0.001mg/m3 (Byte15*256+Byte16)*0.001mg/m3=0.040mg/m3 CO 0.1ppm (Byte17*256+Byte18)*0.1ppm=0.5ppm O3 0.01ppm (Byte19*256+Byte20)*0.01ppm=0.32ppm NO2 0.01ppm (Byte21*256+Byte22)*0.01ppm=0.80ppm 3. Checksum calculation Check value=(invert( Byte1+Byte2+...+Byte7/Byte24))+1 Note: 1. PM2.5 sensor collection hole is the internal airflow inlet, which needs to maintain good contact with the outside air; the fan installation position is the internal airflow outlet of the sensor. When the sensor is installed, please avoid strong airflow around the sensor; if it cannot be avoided, try to keep the direction of the external airflow perpendicular to the direction of the internal airflow of the sensor. 2. When designing the detection chamber of the whole detector, the effective area of the PM2.5 sensor sampling port must be fully considered to ensure the smoothness of the sampling gas path as much as possible. A small sampling area and excessive air resistance will seriously affect the accuracy of the sensor data. 3. Excessive impact or vibration will affect the sensor accuracy and life span, so the sensor should be protected from falling or vibration during installation and use. 4. The PM2.5 sensor on this module is suitable for the detection of dust particles in ordinary indoor environments. The actual use environment should try to avoid soot environment, excessive dust particles, high humidity environment, such as: kitchen, bathroom, smoking room, outdoor, etc. If used in such an environment, appropriate protective measures should be added to prevent viscous particles or large particles from entering the sensor, forming a buildup inside the sensor, and affecting the sensor's performance. 5. The module should avoid contact with organic solvents (including silica gel and other adhesives), coatings, pharmaceuticals, oils and high-concentration gases. |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |