13 / 21 page ![]() HS300x Datasheet © 2021 Renesas Electronics Corporation 13 April 20, 2021 6.7 Status Bits The status bits are used to indicate the current state of the fetched data. The two MSBs of the humidity data byte are the status bits (see the following table). Table 7. Status Bits Status Bits Definition 00B Valid Data: Data that has not been fetched since the last measurement cycle 01B Stale Data: Data that has already been fetched since the last measurement cycle Note: If a data fetch is performed before or during the first measurement after power-on reset, then the stale status will be returned, but this data is actually invalid since the first measurement has not been completed. 6.8 Accessing the Non-volatile Memory The HS300x series non-volatile memory stores its measurement resolution setting and its ID number. To change the sensor resolution or read the ID number, the master must place the HS300x into programming mode while the chip is powering up. The figure below shows the sequence of commands needed to enter the programming mode, which must be sent within 10ms after applying power to the sensor. The master must send the I2C address and a Write bit followed by the command 0xA0|0x00|0x00. Figure 18. Sequence of Commands to Enter Programming Mode This command takes 120µs to process, after which the master has access to the non-volatile memory registers listed in the following table. All of these registers are 16 bits wide. To return to normal sensor operation and perform measurements, the master must send the I2C address and a Write bit, followed by the command: 0x80|0x00|0x00. Table 8. Non-volatile Memory Registers Address Register Description 0x06 Humidity Sensor Resolution – Read Register (bits [11:10]) 0x46 Humidity Sensor Resolution – Write Register (bits [11:10]) 0x11 Temperature Sensor Resolution – Read Register (bits [11:10]) 0x51 Temperature Sensor Resolution – Write Register (bits [11:10]) 0x1E Read Sensor ID – Upper 2 bytes 0x1F Read Sensor ID – Lower 2 bytes |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |