| Motore di ricerca datesheet componenti elettronici |
|
TC80310 Scheda tecnica(PDF) 11 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
TC80310 Scheda tecnica(HTML) 11 Page - NXP Semiconductors |
|
11 / 31 page ![]() NXP Semiconductors 11 80310 5.3.4 Power on reset (POR) When a Power On Reset occurs, product internal registers are reset and the product goes into standby mode. 5.4 Operational modes The following figure describes the battery operating voltage. Figure 8. Battery operating voltage range 4.20 4.40 4.60 4.80 5.00 POR BPA @ POR (V) 4.00 -40.00 -10.00 20.00 50.00 80.00 110.00 140.00 Temp(deg C) MAX RATING 40 V 27 V (1.0 MIN.) 21 V 16.5 V 16 V 13.8 V 10.6 V 8.5 V 5.0 V -2.4 V (5.0 SEC.) DC BATTERY VOLTAGE MAX RATING LOAD DUMP DETECTION, EXCITATION OFF EXCITATION WITH MINIMUM PWM DUTY-CYCLE OVER-VOLTAGE FAULT REGULATION RANGE (PWM REGULATION) EXCITATION AVAILABLE WITH 100% OF DUTY-CYCLE (TARGETED VALUE IN LOGIC RAM) PREVIOUS LOGIC CONFIGURATION IS MAINTAINED. (LAST TARGETED VALUE STORED IN LOGIC RAM). 100% DUTY-CYCLE. NO LRC. LOGIC RESET (DEFAULT TARGET OF REGULATION) DETECTION (16.5 V) |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|