3 / 7 page ![]() AMS116 APPLICATION HINTS Package Power Dissipation The package power dissipation is the level at which the thermal sensor monitoring the junction temperature is activated. The AMS116 shuts down when the junction temperature exceeds the limit of 150 °C. The junction temperature rises as the difference between the input power and output power increases. The mounting pad configuration on the PCB, the board material, as well as the ambient temperature affect the rate of temperature rise. The junction temperature will be low, even if the power dissipation is high, when the mounting of the device has good thermal conductivity. When mounted on the recommended mounting pad (figure1) the power dissipation for the SOT-89 package is 600mW. For operation above 25 °C derate the power dissipation at 4.8mW/ °C. To determine the power dissipation for shutdown when mounted, attach the device on the PCB and increase the input-to-output voltage until the thermal protection circuit is activated. Calculate the power dissipation of the device by subtracting the output voltage from the input voltage and multiply by the output current. The measurements should allow for the ambient temperature of the PCB. The value obtained from PD/ (150°C - TA) is the derating factor. The PCB mounting pad should provide maximum thermal conductivity in order to maintain low device temperatures. As a general rule, the lower the temperature, the better the reliability of the device. The thermal resistance when the device is mounted is equal to: TJ = θJA x PD + TA The internal limit for junction temperature is 150 °C. If the ambient temperature is 25 °C, then: 150 °C = θ JA x PD + 25°C θ JA = 125°C/ PD A simple way to determine PD is to calculate VIN x IIN when the output is shorted. As the temperature rises, the input gradually will decrease. The PD value obtained when the thermal equilibrium is reached, is the value that should be used. The range of usable currents can be found from the graph in figure 2. 4 5 75 150 25 50 6 3 P D D PD T (°C) (mW) Figure 2 Procedure: 1. Find PD. 2. PD1 is calculated as PD x (0.8 - 0.9). 3. Plot PD1 against 25°C. 4. Connect PD1 to the point corresponding to the 150°C. 5. Take a vertical line from the maximum operating temperature (75 °C) to the derating curve. 6. Read the value of PD at the point where the vertical line intersects the derating curve. This is the maximum power dissipation, DPD. The maximum operating current is: IOUT = (DPD/ (VIN(MAX) - VO) External Capacitors The AMS116 series require an output capacitor for device stability. The value required depends on the application circuit and other factors. Because high frequency characteristics of electrolytic capacitors depend greatly on the type and even the manufacturer, the value of capacitance that works well with AMS116 for one brand or type may not necessary be sufficient with an electrolytic of different origin. Sometimes actual bench testing will be the only means to determine the proper capacitor type and value. To obtain stability in all general applications a high quality 100 µF aluminum electrolytic or a 47 µF tantalum electrolytic can be used. A critical characteristic of the electrolytic capacitors is their performance over temperature. The AMS116 is designed to operate to -40 °C, but some electrolytics will freeze around -30°C therefore becoming ineffective. In such case the result is oscillation at the regulator output. For all application circuits where cold operation is necessary, the output capacitor must be rated to operate at the minimum temperature. In applications where the regulator junction temperature will never be lower than 25 °C the output capacitor value can be reduced by a factor of two over the value required for the entire temperature range (47 µF for a high quality aluminum or 22 µF for a tantalum electrolytic capacitor). With higher output currents, the stability of AMS116 decreases. Considering the fact that in many applications the AMS116 is operated at only a few milliamps (or less) of output current, the output capacitor value can be reduced even further. For example, a circuit that is required to deliver a maximum of 10mA of output current from the regulator output will need an output capacitor of only half the value compared to the same regulator required to deliver the full output current of 100mA. As a general rule, with higher output voltages the value of the output capacitance decreases, since the internal loop gain is reduced. In order to determine the minimum value of the output capacitor, for an application circuit, the entire circuit including the capacitor should be bench tested at minimum operating temperatures and maximum operating currents. To maintain internal power dissipation and die heating to a minimum, the input voltage should be maintain at 0.6V above the output. Worst-case occurs just after input power is applied and before the die had the chance to heat up. After the minimum capacitance value has been found for the specific brand and type of electrolytic capacitor, the value should be doubled for actual use to cover for production variations both in the regulator and the capacitor. Advanced Monolithic Systems, Inc. www.advanced-monolithic.com Phone (925) 443-0722 Fax (925) 443-0723 |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |