| Motore di ricerca datesheet componenti elettronici |
|
SL2ICS5301EW/V7 Scheda tecnica(PDF) 20 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
SL2ICS5301EW/V7 Scheda tecnica(HTML) 20 Page - NXP Semiconductors |
|
20 / 33 page ![]() 113730 © NXP B.V. 2007. All rights reserved. Product data sheet Rev. 3.0 — 14 March 2007 20 of 33 NXP Semiconductors SL2 ICS53/SL2 ICS54 I•CODE SLI-S/I•CODE SLI-S HC PUBLIC The requested page(s) is (are) transmitted in the following format and repeated as necessary (depending on number of pages): Table 42. Page protection status byte Page Protection Status byte Block data 00h: page is public (not protected with Read password) or the valid Read password has been transmitted before 16 byte page data content 0Fh: page is protected with the Read password and the valid Read password has not been transmitted before no data If the Option flag in the request is set to 1 the response contains: Table 43. Response format SOF Flags Rest of UID which is not part of the mask and slot number Data CRC16 EOF 8 bits 0 to 64 bit Page status & data 16 bits Multiple of 8 bits Repeated as needed The I•CODE SLI-S/I•CODE SLI-S HC IC reads the requested page(s) including page protection status and sends back their value in the response. Additionally the bytes of the UID, which are not parts of the mask and the slot number in case of 16 slots, are returned. Instead of a padding with zeros up to the next byte boundary the corresponding bits of the UID are returned. The mechanism and timing of the Inventory Page Read command perform the same as at the Inventory command which is described in Clause 8 of ISO/IEC 15693-3. The requested page(s) is (are) transmitted in the following format and repeated as necessary (depending on number of pages): Table 44. Page protection status byte Page Protection Status Byte Block Data 00h: page is public (not protected with Read password) or the valid Read password has been transmitted before 16 byte page data content 0Fh: page is protected with the Read password and the valid Read password has not been transmitted before no data Remark: The number of bits of the re-transmitted UID can be calculated as follows: • 16 slots: – 60 bits (bit 64 to bit 5) - mask length rounded up to the next byte boundary • 1 slot: – 64 bits - mask length rounded up to the next byte boundary |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |