| Motore di ricerca datesheet componenti elettronici |
|
74LVC2G66DP Scheda tecnica(PDF) 4 Page - Nexperia B.V. All rights reserved |
|
|
|||||||||||||||||||||||||||||
74LVC2G66DP Scheda tecnica(HTML) 4 Page - Nexperia B.V. All rights reserved |
|
4 / 22 page ![]() Nexperia 74LVC2G66 Bilateral switch 8. Limiting values Table 5. Limiting values In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V). Symbol Parameter Conditions Min Max Unit VCC supply voltage -0.5 +6.5 V VI input voltage [1] -0.5 +6.5 V IIK input clamping current VI < -0.5 V or VI > VCC + 0.5 V -50 - mA ISK switch clamping current VI < -0.5 V or VI > VCC + 0.5 V - ±50 mA VSW switch voltage enable and disable mode [2] -0.5 VCC + 0.5 V ISW switch current VSW > -0.5 V or VSW < VCC + 0.5 V - ±50 mA ICC supply current - 100 mA IGND ground current -100 - mA Tstg storage temperature -65 +150 °C Ptot total power dissipation Tamb = -40 °C to +125 °C [3] - 250 mW [1] The minimum input voltage rating may be exceeded if the input current rating is observed. [2] The minimum and maximum switch voltage ratings may be exceeded if the switch clamping current rating is observed. [3] For SOT505-2 (TSSOP8) package: Ptot derates linearly with 4.6 mW/K above 96 °C. For SOT765-1 (VSSOP8) package: Ptot derates linearly with 4.9 mW/K above 99 °C. For SOT833-1 (XSON8) package: Ptot derates linearly with 3.1 mW/K above 68 °C. For SOT1116 (XSON8) package: Ptot derates linearly with 4.2 mW/K above 90 °C. 9. Recommended operating conditions Table 6. Operating conditions Symbol Parameter Conditions Min Max Unit VCC supply voltage 1.65 5.5 V VI input voltage 0 5.5 V VSW switch voltage [1] [2] 0 VCC V Tamb ambient temperature -40 +125 °C VCC = 1.65 V to 2.7 V [3] - 20 ns/V Δt/ΔV input transition rise and fall rate VCC = 2.7 V to 5.5 V - 10 ns/V [1] To avoid sinking GND current from terminal nZ when switch current flows in terminal nY, the voltage drop across the bidirectional switch must not exceed 0.4 V. If the switch current flows into terminal nZ, no GND current will flow from terminal nY. In this case, there is no limit for the voltage drop across the switch. [2] For overvoltage tolerant switch voltage capability, refer to 74LVCV2G66. [3] Applies to control signal levels. 74LVC2G66 All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2022. All rights reserved Product data sheet Rev. 13 — 9 September 2022 4 / 22 |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |