| Motore di ricerca datesheet componenti elettronici |
|
HMC1001 Scheda tecnica(PDF) 2 Page - Honeywell Solid State Electronics Center |
|
|
|||||||||||||||||||||||||||||
HMC1001 Scheda tecnica(HTML) 2 Page - Honeywell Solid State Electronics Center |
|
2 / 15 page ![]() LINEAR MAGNETIC FIELD SENSORS 2 HMC1001/1002 SPECIFICATIONS Characteristics Conditions* Min Typ Max Unit Bridge Supply Vbridge referenced to GND 5 12 Volts Bridge Resistance Bridge current = 10mA 600 850 1200 ohm Operating Temperature (4) -55 150 °C Storage Temperature (4) Unbiased -55 175 °C Field Range (4) Full scale (FS), total applied field -2 +2 gauss Linearity Error (4) Best fit straight line ±1 gauss 0.1 0.5 %FS ±2 gauss 1 2 Hysteresis Error (4) 3 sweeps across ±2 gauss 0.05 0.10 %FS Repeatability Error (4) 3 sweeps across ±2 gauss 0.05 0.10 %FS S/R Repeatability (1) 10 S/R Repeatability (2) Output variation after alternate S/R pulses 2 100 µV Bridge Offset Offset = (OUT+) – (OUT-), Field=0 gauss -60 -15 30 mV after Set pulse, Vbridge=8V Sensitivity S/R Current = 3A 2.5 3.2 4.0 mV/V/gauss Noise Density (4) Noise at 1 Hz, Vbridge=5V 29 nV/ Hz Resolution (4) Bandwidth=10Hz, Vbridge=5V 27 µgauss Bandwidth (4) Magnetic signal (lower limit = DC) 5 MHz OFFSET Strap Measured from OFFSET+ to OFFSET- 2.5 3.5 ohm OFFSET Strap Ω Tempco (4) TA = -40 to 125° C 0.39 %/ ° C OFFSET Field (4) Field applied in sensitive direction 46 51 56 mA/gauss Set/Reset Strap Measured from S/R+ to S/R- 1.5 1.8 ohm Set/Reset Current (2) (3) (4) 2 µs current pulse, 1% duty cycle 3.0 3.2 5 Amp Set/Reset Ω Tempco (4) T A = -40 to 125 ° C 0.37 %/ ° C Disturbing Field (4) Sensitivity starts to degrade. 3 gauss Use S/R pulse to restore sensitivity. Sensitivity Tempco (4) T A = -40 to 125 ° C Vbridge=8V -0.32 -0.3 -0.28 %/ ° C Ibridge=5mA -0.06 Bridge Offset Tempco (4) T A = -40 to 125 ° C no Set/Reset ±0.03 %/ ° C Vbridge=5V with Set/Reset ±0.001 Resistance Tempco (4) T A = -40 to 125 ° C 0.25 %/ ° C Cross-Axis Effect (4) Cross field=1gauss no Set/Reset ±3 %FS (see AN-205) with Set/Reset +0.5 Max. Exposed Field (4) No perming effect on zero reading 10000 gauss Weight HMC1001 0.14 gram HMC1002 0.53 (1) VBridge = 4.3V, IS/R = 3.2A, VOUT = VSET – VRESET (2) If VBridge = 8.0V, IS/R = 2.0A, lower S/R current leads to greater output variation. (3) Effective current from power supply is less than 1mA. (4) Not tested in production, guaranteed by characterization. (*) Tested at 25 ° C except otherwise stated. Units: 1 gauss (g) = 1 Oersted (in air), = 79.58 A/m, 1G = 10E-4 Tesla, 1G = 10E5 gamma. |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |