6 / 20 page ![]() Liquisys M CLM223/253 6 Endress+Hauser PROFIBUS DP Signal encoding RS485 Data transmission rate 9.6 kBd, 19.2 kBd, 93.75 kBd, 187.5 kBd, 500 kBd, 1.5 MBd Galvanic isolation Yes (IO modules) Signal on alarm 2.4 or 22 mA in the event of an error Load Max. 500 Ω Transmission range Conductivity Configurable Resistivity Configurable Concentration Configurable actuating variable Configurable Temperature Configurable Signal resolution Max. 700 digits/mA Minimum spread of output signal Conductivity Measured value 0 to 1.999 μS/cm 0.2 μS/cm Measured value 0 to 19.99 μS/cm 2 μS/cm Measured value 20 to 199.9 μS/cm 20 μS/cm Measured value 200 to 1999 μS/cm 200 μS/cm Measured value 2 to 19.99 mS/cm 2 mS/cm Measured value 20 to 2000 mS/cm 20 mS/cm Resistance Measured value 0 to 199.9 kΩcm 20 kΩcm Measured value 200 to 1999 kΩcm 200 kΩcm Measured value 2 to 19.99 MΩcm 2.0 MΩcm Measured value 20 to 200 MΩcm 20 MΩcm Concentration No minimum turndown Temperature 15 °C Separation voltage Max. 350 VRMS / 500 V DC Auxiliary voltage output Output voltage 15 V ± 0.6 V Output current Max. 10 mA Contact outputs Switching current with ohmic load (cos φ = 1) Max. 2 A Switching current with inductive load (cos φ = 0.4) Max. 2 A Switching voltage Max. 250 V AC, 30 V DC Switching power with ohmic load (cos φ = 1) Max. 500 VA AC, 60 W DC Switching power with inductive load (cos φ = 0.4) Max. 500 VA AC, 60 W DC Limit contactors Pickup/dropout delay 0 to 2000 s Controller Function (configurable) Pulse length/pulse frequency controller, continuous controller Controller behavior P, PI, PD, PID, basic load dosing Control gain Kp 0.01 to 20.00 Integral action time Tn 0.0 to 999.9 min Derivative action time Tv 0.0 to 999.9 min Period length for pulse length controller 0.5 to 999.9 s Frequency for pulse frequency controller 60 to 180 min-1 Basic load 0 to 40 % of max. actuating variable |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |