Back Button 6281 Datasheet HTML 5Page - Christian Bürkert GmbH & Co. KG 6281 Datasheet HTML 6Page - Christian Bürkert GmbH & Co. KG 6281 Datasheet HTML 7Page - Christian Bürkert GmbH & Co. KG 6281 Datasheet HTML 8Page - Christian Bürkert GmbH & Co. KG 6281 Datasheet HTML 9Page - Christian Bürkert GmbH & Co. KG 6281 Datasheet HTML 10Page - Christian Bürkert GmbH & Co. KG 6281 Datasheet HTML 11Page - Christian Bürkert GmbH & Co. KG 6281 Datasheet HTML 12Page - Christian Bürkert GmbH & Co. KG 6281 Datasheet HTML 13Page - Christian Bürkert GmbH & Co. KG Next Button
Zoom Inzoom in Zoom Outzoom out
 9 / 16 page
background image
Type 8750
9 | 14
Visit product website 
Nominal diame-
ter (pipe)
Seat size
Actuator
size
K
V value at stroke [m
3
/h]
K
VS
value
DN
NPS
5 %
10 %
30 %
50 %
70 %
90 %
[m3/h]
80
3"
50
130 (P)
1.0
1.2
3.4
8.3
19.0
35.0
45.0
65
130 (P )
1.6
2.0
5.0
13.0
35.0
61
73
225 (L)
1.4
1.7
3.8
8.2
19.5
50
70
80
130 (P)
2.5
3.4
10.7
27.0
58
87
100
225 (L)
2.1
2.6
7.0
16.0
40.0
83
100
100
4"
65
130 (P)
1.4
1.8
5.0
15.0
37.0
64
77
225 (L)
1.4
1.7
3.8
8.3
20.0
51
75
80
130 (P)
2.2
3.1
10.3
30.0
66
97
110
225 (L)
2.1
2.6
7.0
17.0
44.0
89
115
100
130 (P)
3.8
5.2
15.0
46.5
90
128
140
225 (L)
3.2
3.9
9.0
20.5
51
118
140
6.
Product operation
6.1. Flow measurement principle
The valve seat of the control valve represents a variable orifice. By measuring the pressure upstream and downstream of this orifice
and a programmed flow characteristic of the corresponding valve, the current flow rate can be determined. This is compared with the
flow setpoint transmitted to the unit. In the event of a control deviation, the valve and thus the orifice are adjusted exactly so that the
setpoint and actual value match. To determine the flow rate, the density of the gas and the reference conditions, among other things,
must be set in the controller during commissioning. The temperature of gas that is usually present is also permanently programmed
in. The control parameters of the PI controller must also be determined and set during commissioning. If the outlet pressure fluctu-
ates, the unit automatically reacts to this by detecting a control deviation between the setpoint and actual value and adjusting the
valve so that this disappears.
7.
Product installation
7.1. Piping upstream of the fluid flow regulator
For high accuracy, the inlet distances upstream of the fluid quantity regulator must be observed in accordance with EN ISO 5167 - 1.
The outlet section downstream of the valve is already integrated in the system. Depending on the installation situation, an inlet dis-
tance corresponding to 15…20 times the pipe diameter is recommended.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


Scheda tecnica Scarica

Go To PDF Page


Link URL



Lei ha avuto il aiuto da alldatasheet?  [ DONATE ] 

Di alldatasheet   |   Richest di pubblicita   |   contatti   |   Privacy Policy   |   Collegamento alla scheda tecnica    |   scambio Link   |   Ricerca produttore
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com