9 / 16 page ![]() Type 8750 9 | 14 Visit product website Nominal diame- ter (pipe) Seat size Actuator size K V value at stroke [m 3 /h] K VS value DN NPS 5 % 10 % 30 % 50 % 70 % 90 % [m3/h] 80 3" 50 130 (P) 1.0 1.2 3.4 8.3 19.0 35.0 45.0 65 130 (P ) 1.6 2.0 5.0 13.0 35.0 61 73 225 (L) 1.4 1.7 3.8 8.2 19.5 50 70 80 130 (P) 2.5 3.4 10.7 27.0 58 87 100 225 (L) 2.1 2.6 7.0 16.0 40.0 83 100 100 4" 65 130 (P) 1.4 1.8 5.0 15.0 37.0 64 77 225 (L) 1.4 1.7 3.8 8.3 20.0 51 75 80 130 (P) 2.2 3.1 10.3 30.0 66 97 110 225 (L) 2.1 2.6 7.0 17.0 44.0 89 115 100 130 (P) 3.8 5.2 15.0 46.5 90 128 140 225 (L) 3.2 3.9 9.0 20.5 51 118 140 6. Product operation 6.1. Flow measurement principle The valve seat of the control valve represents a variable orifice. By measuring the pressure upstream and downstream of this orifice and a programmed flow characteristic of the corresponding valve, the current flow rate can be determined. This is compared with the flow setpoint transmitted to the unit. In the event of a control deviation, the valve and thus the orifice are adjusted exactly so that the setpoint and actual value match. To determine the flow rate, the density of the gas and the reference conditions, among other things, must be set in the controller during commissioning. The temperature of gas that is usually present is also permanently programmed in. The control parameters of the PI controller must also be determined and set during commissioning. If the outlet pressure fluctu- ates, the unit automatically reacts to this by detecting a control deviation between the setpoint and actual value and adjusting the valve so that this disappears. 7. Product installation 7.1. Piping upstream of the fluid flow regulator For high accuracy, the inlet distances upstream of the fluid quantity regulator must be observed in accordance with EN ISO 5167 - 1. The outlet section downstream of the valve is already integrated in the system. Depending on the installation situation, an inlet dis- tance corresponding to 15…20 times the pipe diameter is recommended. |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |