| Motore di ricerca datesheet componenti elettronici |
|
DER-58 Scheda tecnica(PDF) 17 Page - Power Integrations, Inc. |
|
|
|||||||||||||||||||||||||||||
DER-58 Scheda tecnica(HTML) 17 Page - Power Integrations, Inc. |
|
17 / 22 page ![]() DER-58 Wide-range Flyback using LNK304 May 4, 2005 Page 17 of 22 Power Integrations, Inc. Tel: +1 408 414 9200 Fax: +1 408 414 9201 www.powerint.com 10.4. Load Transient Response at 120VAC (50% to 100% Load Step) In the figures shown below, signal averaging was used to better enable viewing the load transient response. The oscilloscope was triggered using the load current step as a trigger source. Since the output switching and line frequency occur essentially at random with respect to the load transient, contributions to the output ripple from these sources will average out, leaving the contribution only from the load step response. Figure 12 – Transient Response +5V, 50%-100%-50% Load Step. Load Current, 100mA/div. Output Voltage 1V, 2ms / div. (+12V Offset) |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|