| Motore di ricerca datesheet componenti elettronici |
|
24LC00T-/ST Scheda tecnica(PDF) 9 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
24LC00T-/ST Scheda tecnica(HTML) 9 Page - Microchip Technology |
|
9 / 22 page ![]() 2004 Microchip Technology Inc. DS21226E-page 9 24LCS61/24LCS62 TABLE 5-1: COMMAND SUMMARY TABLE Command Result if Device Has Not Yet Been Assigned an ID Byte Result if Device Has Already Been Assigned an ID Byte Assign Address command If device wins arbitration, then ID byte will become xxh. If device loses arbitration, then ID byte will revert back to 00h. Device will not acknowledge command. Clear Address command Device will remain with ID byte set to 00h. Device ID byte will revert back to 00h and will then acknowledge Assign Address commands. Read or Write command with ID byte set to 00h Since the default ID byte for the device is 00h, the device will execute the command. Device will acknowledge the control byte, but it will not acknowledge any further bytes and will not respond to the command. Read or Write command with ID byte set to xxh (other than 00h) Device will acknowledge the control byte, but it will not acknowl- edge any further bytes and will not respond to the command. If the device ID byte matches the ID byte in the command (xxh), the device will execute the command. If the device ID byte does not match the ID byte in the command, then the device will acknowledge the control byte, but it will not acknowledge any further bytes and will not respond to the command. Set Write-Protect command with ID byte set to 00h Since the default ID address for the device is 00h, the device will execute the command. Device will acknowledge the control byte, but it will not acknowledge any further bytes and will not respond to the command. Set Write Protection command with ID byte set to xxh (other than 00h) Device will acknowledge the control byte, but it will not acknowl- edge any further bytes and will not respond to the command. If the device ID byte matches the ID byte in the command (xxh), the device will execute the command. If the device ID byte does not match the ID byte in the command, then the device will acknowledge the control byte, but it will not acknowledge any further bytes and will not respond to the command. Note: Once this command has been executed successfully for a device, the device will no longer acknowledge any part of this command again. |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |