Motore di ricerca datesheet componenti elettronici
  Italian  ▼
ALLDATASHEETIT.COM

X  

M34571GDFP Scheda tecnica(PDF) 77 Page - Renesas Technology Corp

Il numero della parte M34571GDFP
Spiegazioni elettronici  SINGLE-CHIP 4-BIT CMOS MICROCOMPUTER
PDF  126 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Produttore elettronici  RENESAS [Renesas Technology Corp]
Homepage  http://www.renesas.com
Logo RENESAS - Renesas Technology Corp

M34571GDFP Scheda tecnica(HTML) 77 Page - Renesas Technology Corp

Back Button M34571GDFP Datasheet HTML 73Page - Renesas Technology Corp M34571GDFP Datasheet HTML 74Page - Renesas Technology Corp M34571GDFP Datasheet HTML 75Page - Renesas Technology Corp M34571GDFP Datasheet HTML 76Page - Renesas Technology Corp M34571GDFP Datasheet HTML 77Page - Renesas Technology Corp M34571GDFP Datasheet HTML 78Page - Renesas Technology Corp M34571GDFP Datasheet HTML 79Page - Renesas Technology Corp M34571GDFP Datasheet HTML 80Page - Renesas Technology Corp M34571GDFP Datasheet HTML 81Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 77 / 126 page
background image
Rev.1.02
May 25, 2007
Page 77 of 124
REJ03B0179-0102
4571 Group
MACHINE INSTRUCTIONS (INDEX BY ALPHABET) (continued)
LXY x,y
(Load register X and Y with x and y)
Instruc-
tion
code
D9
D0
Number of
words
Number of
cycles
Flag CY
Skip condition
11 x3 x2 x1 x0 y3 y2 y1 y0 2 3x y 16
11
-
Continuous
description
Opera-
tion:
(X)
← x x = 0 to 15
(Y)
← y y = 0 to 15
Grouping:
RAM addresses
Description: Loads the value x in the immediate field to register X, and
the value y in the immediate field to register Y. When the
LXY instructions are continuously coded and executed,
only the first LXY instruction is executed and other LXY
instructions coded continuously are skipped.
LZ z
(Load register Z with z)
Instruc-
tion
code
D9
D0
Number of
words
Number of
cycles
Flag CY
Skip condition
0
0
0
100
10 Z1 Z0 2 04
8
+z 16
1
1
-
-
Opera-
tion:
(Z)
← z z = 0 to 3
Grouping:
RAM addresses
Description: Loads the value z in the immediate field to register Z.
NOP
(No OPeration)
Instruc-
tion
code
D9
D0
Number of
words
Number of
cycles
Flag CY
Skip condition
0
0
0
000
00
00 2 00 0 16
11
-
-
Opera-
tion:
(PC)
← (PC) + 1
Grouping:
Other operation
Description: No operation; Adds 1 to program counter value, and others
remain unchanged.
OP0A
(Output port P0 from Accumulator)
Instruc-
tion
code
D9
D0
Number of
words
Number of
cycles
Flag CY
Skip condition
1
0
0
010
00
00 2 22 0 16
11
-
-
Opera-
tion:
(P0)
← (A)
Grouping:
Input/Output operation
Description: Outputs the contents of register A to port P0.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Scheda tecnica Scarica

Go To PDF Page


Link URL



Lei ha avuto il aiuto da alldatasheet?  [ DONATE ] 

Di alldatasheet   |   Richest di pubblicita   |   contatti   |   Privacy Policy   |   Collegamento alla scheda tecnica    |   scambio Link   |   Ricerca produttore
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com