| Motore di ricerca datesheet componenti elettronici |
|
E5CN-R2TU Scheda tecnica(PDF) 21 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E5CN-R2TU Scheda tecnica(HTML) 21 Page - Omron Electronics LLC |
|
21 / 24 page ![]() Digital Temperature Controllers E5CN/E5CN-U 21 Precautions Note: Refer to the ntlp: Electronic Temperature Controller Catalog (Cat. No. ntlp) for common precautions. Note: 1. An SELV circuit is one separated from the power supply with double insulation or reinforced insulation, that does not exceed 30 V r.m.s. and 42.4 V peak or 60 VDC. 2. A class 2 power supply is one tested and certified by UL as have the current and voltage of the secondary output restricted to specific levels. Precautions for Safe Use 1. Do not use the Temperature Controller in the following locations. • Locations exposed to radiated heat from heating devices • Locations subject to exposure to water or oil • Locations subject to direct sunlight • Locations subject to dust or corrosive gas (especially sulfide gas or ammonia gas). • Locations subject to severe temperature changes • Locations subject to icing or condensation • Locations subject vibration or strong shock 2. Use and store the Temperature Controller within the rated ambient temperature and humidity. When two or more Temperature Controllers are mounted horizontally close to each other or vertically next to one another, the internal temperature will increase due to heat radiated by the Temperature Controllers and the service life will decrease. In such a case, use forced cooling by fans or other means of air ventilation to cool down the Temperature Controllers. 3. Allow enough space around the Temperature Controller to ensure proper heat dissipation. Do not block the ventilating holes. 4. Be sure to wire terminals properly using the correct polarity. 5. Use crimp terminals with the specified dimensions (M3.5, width 7.2 mm max.). Use wires of a thickness of AWG24 (0.205 mm2) to AWG14 (2.081 mm2). The exposed current-carrying part to be inserted into terminals must be 5 to 6 mm. 6. Do not connect anything to unused terminals. 7. Allow as much space as possible between the Controller and devices that generate powerful high frequencies (high-frequency welders, high-frequency sewing machines, etc.) or surge. Keep the wiring for the Temperature Controller's terminal block away from power cables carry high voltages or large currents. Also, do not wire power lines together with or parallel to Temperature Controller wiring. 8. Use the Temperature Controller within a power supply voltage and load that meet all specifications and ratings. 9. Set up the power supply so that the voltage will reach the rated voltage within 2 seconds after turning ON. 10. Allow at least 30 minutes for the Temperature Controller to warm up. 11. When using self-tuning, turn ON power for the load (e.g., heater) at the same time as or before supplying power to the Temperature Controller. 12. Install the appropriate switches and circuit breakers and label them accordingly so that power can be turned OFF in an emergency by the person operating the Temperature Controller. 13. If you remove the Controller from its case, do not touch or apply shock to the electronic parts inside. When placing the Controller back in the case, make sure that electronic parts do not come in contact with the case. 14. Use alcohol to clean the Temperature Controller. Do not use thinner or other solvent-based substances. 15. It will require 2 seconds for the outputs from the Temperature Controller to stabilize after turning ON the power supply. Design the system (e.g., the control panel) to allow for this time. 16. Outputs will turn OFF depending on the mode when switching to the initial setting mode. Confirm system safety before switching the mode. Do not touch any of the terminals while the power is being supplied. Doing so may occasionally result in minor electric shock. Do not allow pieces of metal or wire cuttings to get inside the Temperature Controller. Failure to do so may occasionally result in minor electric shock, fire, or damage to equipment. Do not use the Temperature Controller in locations subject to flammable or explosive gas. Doing so may occasionally result in minor injury due to explosion. Do not attempt to disassemble, modify, or repair the Temperature Controller or touch any internal components. Doing so may occasionally result in minor electric shock, fire, or damage to equipment. Caution: Danger of Electric Shock a) This Temperature Controller is UL-listed as an open- type process controller. Use it in a control panel structure so that fire will not leave the panel. b) When using two or more cutoff switches, turn OFF all switches so that no power is supplied to the Temperature Controller before maintenance or inspections. c) Signal inputs are SELV restricted circuits. (See note 1.) d) Caution: To reduce the danger of fire or electric shock, do not internally connect the outputs of different class 2 circuits. (See note 2.) If the output relay is used beyond its life expectancy, its contacts may occasionally become fused or burned. Always consider the actual application conditions and be sure to use the output relay within its rated load and electrical life expectancy. The life expectancy of the output relay varies considerably according to its switching capacity and operating conditions. Fire may occasionally occur if terminal screws become loose. Tighten the terminal screws using a torque between 0.74 and 0.90 N·m. Make settings for the Temperature Controller that are suitable for the controlled system. Failure to do so may result in unexpected operation occasionally resulting in damage to equipment or personal injury. Warning: To reduce the danger or electric shock or fire, use the Temperature Controller in an controlled environment relatively free from polluting materials. Take appropriate safety measures, such as installing a separate monitoring system, to ensure safe operation in the event of a malfunction of the Temperature Controller. Loss of operation control or alarm outputs due to malfunction may occasionally result in physical damage to the controlled system or equipment. !CAUTION |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |