| Motore di ricerca datesheet componenti elettronici |
|
P2CF-08 Scheda tecnica(PDF) 5 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
P2CF-08 Scheda tecnica(HTML) 5 Page - Omron Electronics LLC |
|
5 / 22 page ![]() Solid-state Multi-functional Timer H3CR-A B-113 I Characteristics Note: 1. The value is ±5% FS +100 ms to −0 ms max. when the C, D, or G mode signal of the H3CR-AP is OFF. 2. Refer to the Life-test Curve. Accuracy of operating time ±0.2% FS max. (±0.2%±10 ms max. in a range of 1.2 s) Setting error ±5% FS ±50 ms (see note 1) Reset time Min. power-opening time: 0.1 s max. Min. pulse width: 0.05 s (H3CR-A/-AS) Reset voltage 10% max. of rated supply voltage Influence of voltage ±0.2% FS max. (±0.2%±10 ms max. in a range of 1.2 s) Influence of tempera- ture ±1% FS max. (±1%±10 ms max. in a range of 1.2 s) Insulation resistance 100 M Ω min. (at 500 VDC) Dielectric strength 2,000 VAC (1,000 VAC for H3CR-A @S), 50/60 Hz for 1 min (between current-carrying metal parts and exposed non- current-carrying metal parts) 2,000 VAC (1,000 VAC for H3CR-A @S), 50/60 Hz for 1 min (between control output terminals and operating circuit) 2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities) 1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other) 2,000 VAC, 50/60 Hz for 1 min (between input and control output terminals and operation circuit) for H3CR-AP Impulse withstand voltage 3 kV (between power terminals) for 100 to 240 VAC/100 to 125 VDC, 1 kV for 24 to 48 VAC/12 to 48 VDC 4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC/100 to 125 VDC, 1.5 kV for 24 to 48 VAC/12 to 48 VDC and 24 to 48 VAC/VDC Noise immunity ±1.5 kV (between power terminals) and ±600 V (between no-voltage input terminals), square-wave noise by noise sim- ulator (pulse width: 100 ns/1 µs, 1-ns rise) Static immunity Malfunction: 8 kV Destruction: 15 kV Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm single amplitude each in 3 directions for 2 hours each Malfunction: 10 to 55 Hz with 0.5-mm single amplitude each in 3 directions for 10 minutes each Shock resistance Destruction: 1,000 m/s2 3 times each in 6 directions Malfunction: 100 m/s2 3 times each in 6 directions Ambient temperature Operating: −10°C to 55°C (with no icing) Storage: −25°C to 65°C (with no icing) Ambient humidity Operating: 35% to 85% Life expectancy Mechanical: 20,000,000 operations min. (under no load at 1,800 operations/h) Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h) (see note 2) EMC (EMI) EN61812-1 Emission Enclosure: EN55011 Group 1 class A Emission AC Mains: EN55011 Group 1 class A (EMS) EN61812-1 Immunity ESD: IEC61000-4-2: 6 kV contact discharge (level 3) 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: IEC61000-4-3:10 V/m (80 MHz to 1 GHz) (level 3) Immunity RF-interference from Pulse-modulated Radio Waves:IEC61000-4-3:10 V/m (900 ±5 MHz) (level 3) Immunity Conducted Disturbance: IEC61000-4-6: 10 V (0.15 to 80 MHz) (level 3) Immunity Burst: IEC61000-4-4: 2 kV power-line (level 3) 2 kV I/O signal-line (level 4) Immunity Surge: IEC61000-4-5: 1 kV line to line (level 3) 2 kV line to ground (level 3) Case color Light gray (Munsell 5Y7/1) Degree of protection IP40 (panel surface) Weight Approx. 90 g |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |