| Motore di ricerca datesheet componenti elettronici |
|
BFD0003 Scheda tecnica(PDF) 2 Page - Balluff Korea Ltd. |
|
|
|||||||||||||||||||||||||||||
BFD0003 Scheda tecnica(HTML) 2 Page - Balluff Korea Ltd. |
|
2 / 2 page ![]() Smart Automation and Monitoring System Ultrasonic Sensors BFD 3SAP-19N000-U01-LA2-CA2000 Order Code: BFD0003 Internet www.balluff.com eCl@ss 9.1: 27-27-28-03 Subject to change without notice: 289053 ETIM 6.0: EC001846 BFD0003_1.8_2024-11-18 2 / 2 Interface Analog output Analog, voltage/Analog, current selectable 4…20 mA/0…10 V Baud rate COM3 (230,4 kBaud) Interface IO-Link 1.1 Process data IN 6 bytes Process data OUT 0 bytes Process data cycle min. 1.4 ms Switching output Pin 2: PNP/NPN/push-pull NO/NC Pin 4: Push-pull NO/NC Material Gasket, material NBR Housing material 1.4104 stainless steel PBT Material jacket TPU Sealing ring, standard DIN 3869-18-NBR Mechanical data Burst pressure 455 bar Dimension Ø 30 x 30.9 mm Mounting connection M18x1 Pressure rating max. 350 bar Pressure rating, note oil pressure rated Sealing ring, size 20.9 × 15.7 × 1.5 mm Size Screw design Tightening torque max. 62 Nm Tightening torque min. 58 Nm Weight 98 g Range/Distance Measuring range 0...80 mm Measuring rate max. 500 Hz (digital) 1000 Hz (analog) Non-linearity max. ±250 µm Repeat accuracy ± 50 µm Resolution ≤ 12 bits Resolution analog 12 Bit Resolution digital 1 µm Temperature drift max. 5 % Remarks For reliable operation, the sensor must have direct contact with the fluid. Ensure that the hydraulic circuit is free of air before operating the measuring system. For safe and reliable operation, prepare the mechanical connection of the hydraulic cylinder according to the instructions. The sensor is functional again after the overload has been eliminated. For additional information, refer to user's guide. For more information about MTTF and B10d see MTTF / B10d Certificate Indication of the MTTF- / B10d value does not represent a binding composition and/or life expectancy assurance; these are simply experiential values with no warranty implications. These declared values also do not extend the expiration period for defect claims or affect it in any way. Wiring Diagrams (Schematic) |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |