| Motore di ricerca datesheet componenti elettronici |
|
E5CS-RKJX Scheda tecnica(PDF) 9 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E5CS-RKJX Scheda tecnica(HTML) 9 Page - Omron Electronics LLC |
|
9 / 12 page ![]() E5CS-X E5CS-X 9 Input Shift Function This function is used to shift the value displayed in the main display from the value actual measured by a desired amount. This powerful feature can be used for “fine tuning” compensation, while leaving the set temperature unaffected. The input shift function is activated by setting pin 4 of the internal DIP switch to ON. ON 16 5 4 3 2 PX ON This allows the setting of the temperature shift value. Press the tem- perature indication switching ( ) key repeatedly until “H 0” (in this case, indicating a zero input shift) is displayed on the main display. Then set the input shift value by using the upward and downward setting keys. Example Main display Temperature measured by sensor Temperature displayed (without shift) 100 °C 100 °C (offset by +9 °C) 100 °C 109 °C (offset by –16 °C) 100 °C 84 °C The input shift value can be set within a range of –99 to 99, except with a 0.0 to 99.9 platinum resistance thermometer, where the input shift narrows to a range of –9.9 to 9.9. When the desired shift has been entered, set pin 4 to OFF. The input shift value remains in memory. Consequently, if the input shift func- tion is not needed, with pin 4 activated set the input shift value to 0. Sensor Failure Operation Thermocouple Type Condition Display Control output Break in sensor blinks OFF Note: When the input is short-circuited, the room temperature is displayed. Platinum Resistance Thermometer Type Condition Display Control output Break in sensor blinks OFF blinks OFF Disconnection of two or three wires blinks OFF Short-circuit blinks OFF Note: The resistance of the platinum resistance thermometer is 100 Ω at 0°C. It increases to about 140 Ω at 100°C. Thermistor Type Condition Display Control output Break in sensor ON during heating (reverse) OFF during cooling (normal) Short-circuit ON during heating (reverse) OFF during cooling (normal) |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |