353C Scheda tecnica(HTML) 3 Page - Automatic Timing & Controls, Inc. |
|
3 / 3 page ![]() 103 Automatic Timing & Controls 800.727.5646 atcdiversified.com OPERATION TYPICAL INSTALLATION DELAYED MODE — Sustained* start INTERVAL MODE — Sustained* or momentary** start INTERVAL MODE — Sustained* start REPEAT CYCLE PULSE GENERATOR — Uninterrupted start signal The Shawnee 353 operates on a digital logic circuit with three main elements: a clock which uses utility line frequency of 50 or 60 Hz as its time base; a read-only-memory (ROM) whose output is set by the timer’s digital setting number wheels; and a comparator that continuously examines the outputs of the clock and ROM. When power is applied (start signal on), the clock begins to count each cycle of the utility line frequency. Translating this count into hundredths of a second, the clock accumulates it and feeds it continuously to the comparator. When clock output exactly equals the output of the ROM, the 353 times out. At that instant, the clock turns itself off automatically. At the same instant, the 353 generates one type of control action or another, depending on how it is wired. When the 353 is wired for interval operation, the timer’s output device (either the standard SPDT relay or the optional SPST switch module) is energized from the start to the end of the time cycle; so is the -24 VDC output at terminal 16. When the 353 is wired for delayed control, the output device is energized at the end of the cycle and remains on until the timer is reset; so is the -24 VDC output. When the 353 is wired as a repeat cycle pulse generator, the output device and the DC signal are both off until the end of the cycle, at which time they are both on for about 80 mSEC. The length of the pulse is included in the time cycle: the cycle runs from the start of one pulse to the start of the next. The 353 automatically starts a new cycle immediately after reset. The duration of the standard output pulse generated by the 353 is 80 mSEC (±20 mSEC), but it can be easily lengthened or shortened by using a capacitor or resistor across terminals 4 and 11. To shorten the output pulse, the size of the resistor (fixed or variable) is calculated as follows: Where: t = time in milliseconds (± 25%) 2.2t - 2.64 _________ = R 80-t R = resistance in megohms (must be at least 0.2 megohm.) To lengthen the output pulse, the size of the capacitor is calculated as follows: Where: T = time in seconds (± 25%) T - 0.08 _________ = C 1.6 C = capacitance in microfarads. NOTE Observe Polarity: (+) Terminal of the capacitor goes to 11, (–) Terminal to 4. To start from AC voltage, jumper terminals 8-9 and 4-11 and start with AC power at terminals 1 and 2. *Start switch must be closed — or DC start signal must be on — for entire cycle. Timer resets when start switch opens or DC start signal turns off. To start from DC voltage, apply external ground on 11 and start signal on 9. **Start switch may be closed — or DC start signal may be on — for less that the entire cycle. Timer resets at end of cycle. Automatic Timing & Controls 800.727.5646 atcdiversified.com |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |