26 / 59 page ![]() CC1000 SWRS048A Page 26 of 55 Write CAL: CAL_START=0 End of calibration Wait for maximum 34 ms, or Read CAL and wait until CAL_COMPLETE=1 Start single calibration RX frequency register A is calibrated first Write MAIN: RXTX = 0; F_REG = 0 RX_PD = 0; TX_PD = 1; FS_PD = 0 CORE_PD = 0; BIAS_PD = 0; RESET_N=1 Write FREQ_A, FREQ_B If DR>=9.6kBd then write TEST4: L2KIO=3Fh Write CAL: CAL_DUAL = 0 Frequency register A is used for RX mode, register B for TX Write CAL: CAL_START=1 Calibration is performed in RX mode, Result is stored in TEST0 and TEST2, RX register Write CURRENT = RX current Write PLL = RX pll Update CURRENT and PLL for RX mode Write CAL: CAL_START=0 Wait for 34 ms, or Read CAL and wait until CAL_COMPLETE=1 TX frequency register B is calibrated second Write MAIN: RXTX = 1; F_REG = 1 RX_PD = 1; TX_PD = 0; FS_PD = 0 CORE_PD = 0; BIAS_PD = 0; RESET_N=1 Write CAL: CAL_START=1 Calibration is performed in TX mode, Result is stored in TEST0 and TEST2, TX registers Write CURRENT = TX current Write PLL = TX pll Write PA_POW = 00h Update CURRENT and PLL for TX mode PA is turned off to prevent spurious emission Calibration time depend on the reference frequency, see text. Write CAL: CAL_START=0 End of calibration Wait for maximum 34 ms, or Read CAL and wait until CAL_COMPLETE=1 Start single calibration RX frequency register A is calibrated first Write MAIN: RXTX = 0; F_REG = 0 RX_PD = 0; TX_PD = 1; FS_PD = 0 CORE_PD = 0; BIAS_PD = 0; RESET_N=1 Write FREQ_A, FREQ_B If DR>=9.6kBd then write TEST4: L2KIO=3Fh Write CAL: CAL_DUAL = 0 Frequency register A is used for RX mode, register B for TX Write CAL: CAL_START=1 Calibration is performed in RX mode, Result is stored in TEST0 and TEST2, RX register Write CURRENT = RX current Write PLL = RX pll Update CURRENT and PLL for RX mode Write CAL: CAL_START=0 Wait for 34 ms, or Read CAL and wait until CAL_COMPLETE=1 TX frequency register B is calibrated second Write MAIN: RXTX = 1; F_REG = 1 RX_PD = 1; TX_PD = 0; FS_PD = 0 CORE_PD = 0; BIAS_PD = 0; RESET_N=1 Write CAL: CAL_START=1 Calibration is performed in TX mode, Result is stored in TEST0 and TEST2, TX registers Write CURRENT = TX current Write PLL = TX pll Write PA_POW = 00h Update CURRENT and PLL for TX mode PA is turned off to prevent spurious emission Calibration time depend on the reference frequency, see text. Figure 16. Single calibration algorithm for RX and TX |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |