26 / 36 page ![]() 26 Sending Commands and Data When sending commands to the meter, a string containing at least one command character must be constructed. A command string consists of a command character, a value identifier, numerical data (if writing data to the meter) followed by a the command terminator character * or $. Command Chart Register Identification Chart Command Description Notes N Node Address Specifier Address a specific meter. Must be followed by one or two digit node address. Not required when node address = 0. T Transmit Value (read) Read a register from the meter. Must be followed by register ID character. V Value change (write) Write to register of the meter. Must be followed by register ID character and numeric data. R Reset Reset a register or output. Must be followed by register ID character P Block Print Request (read) Initiates a block print output. Registers are defined in programming. ID Value Description Register ID Applicable Commands/Comments A Input INP (Reset command [Ver2.5+] zeros the input [“REL” or Tare]) B Total TOT (Reset command resets total to zero) C Max Input MAX (Reset command resets MAX to current reading) D Min Input MIN (Reset command resets MIN to current reading) E Setpoint 1 SP1 (Reset command resets the setpoint output) F Setpoint 2 SP2 (Reset command resets the setpoint output) G Setpoint 3 SP3 (Reset command resets the setpoint output) H Setpoint 4 SP4 (Reset command resets the setpoint output) I Analog Output Register AOR (Applies to manual mode) Q L J Offset/Tare (PAXS) Absolute (gross) input display value Control Status Register OFS TAR † ABS GRS † CSR (Ver 2.5+) T, P, R T, P, R T, P, R T, P, R T, P, V, R T, P, V, R T, P, V, R T, P, V, R T, V T, P, V T, P T, V Command String Construction The command string must be constructed in a specific sequence. The meter does not respond with an error message to illegal commands. The following procedure details construction of a command string: 1. The first 2 or 3 characters consist of the Node Address Specifier (N) followed by a 1 or 2 character node address number. The node address number of the meter is programmable. If the node address is 0, this command and the node address itself may be omitted. This is the only command that may be used in conjunction with other commands. 2. After the optional address specifier, the next character is the command character. 3. The next character is the register ID. This identifies the register that the command affects. The P command does not require a register ID character. It prints according to the selections made in print options. 4. If constructing a value change command (writing data), the numeric data is sent next. 5. All command strings must be terminated with the string termination characters * or $. The meter does not begin processing the command string until this character is received. See timing diagram figure for differences of * and $ terminating characters. Command String Examples: 1. Node address = 17, Write 350 to Setpoint 1, response delay of 2 msec min String: N17VE350$ 2. Node address = 5, Read Input value, response delay of 50 msec min String: N5TA* 3. Node address = 0, Reset Setpoint 4 output, response delay of 50 msec min String: RH* Sending Numeric Data Numeric data sent to the meter must be limited to 5 digits (-19,999 to 99,999). If more than 5 digits are sent, the meter accepts the last 5. Leading zeros are ignored. Negative numbers must have a minus sign. The meter ignores any decimal point and conforms the number to the scaled resolution. (For example: the meter’s scaled decimal point position = 0.0 and 25 is written to a register. The value of the register is now 2.5 In this case, write a value = 25.0). Note: Since the meter does not issue a reply to value change commands, follow with a transmit value command for readback verification. Receiving Data Data is transmitted by the meter in response to either a transmit command (T), a print block command (P) or User Function print request. The response from the meter is either a full field transmission or an abbreviated transmission. In this case, the response contains only the numeric field. The meter response mode is established in programming. Full Field Transmission * These characters only appear in the last line of a block print. The first two characters transmitted are the node address, unless the node address assigned =0, in which case spaces are substituted. A space follows the node address field. The next three characters are the register ID (Serial Mnemonic). The numeric data is transmitted next. The numeric field is 12 characters long (to accommodate the 10 digit totalizer), with the decimal point position floating within the data field. Negative value have a leading minus sign. The data field is right justified with leading spaces. The end of the response string is terminated with a carriage return <CR> and <LF>. When block print is finished, an extra <SP><CR> <LF> is used to provide separation between the blocks. Abbreviated Transmission * These characters only appear in the last line of a block print. The abbreviated response suppresses the node address and register ID, leaving only the numeric part of the response. Meter Response Examples: 1. Node address = 17, full field response, Input = 875 17 INP 875 <CR><LF> 2. Node address = 0, full field response, Setpoint 2 = -250.5 SP2 -250.5<CR><LF> 3. Node address = 0, abbreviated response, Setpoint 2 = 250, last line of block print 250<CR><LF><SP><CR><LF> Byte Description 1, 2 2 byte Node Address field [00-99] 3 <SP> (Space) 4-6 3 byte Register Mnemonic field 7-18 19 <CR> carriage return 20 <LF> line feed 21 <SP>* (Space) 22 <CR>* carriage return 23 <LF>* line feed Byte Description 1-12 12 byte data field, 10 bytes for number, one byte for sign, one byte for decimal point 13 <CR> carriage return 14 <LF> line feed 15 <SP>* (Space) 16 <CR>* carriage return 17 <LF>* line feed 12 byte data field; 10 bytes for number, one byte for sign, one byte for decimal point (The T command may be a different byte length) † -Register ID for the PAXS. |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |