| Motore di ricerca datesheet componenti elettronici |
|
INLC10AQ-R4.5 Scheda tecnica(PDF) 20 Page - inova Semiconductors |
|
|
|||||||||||||||||||||||||||||
INLC10AQ-R4.5 Scheda tecnica(HTML) 20 Page - inova Semiconductors |
|
20 / 35 page ![]() Datasheet DS_INLC10AQ Revision 1.0_B Inova Semiconductors Confidential Page 20 of 35 4.1.7 Read Access A read access consists of two phases, the command and the response phase. The command phase uses downstream communication and the response phase uses upstream communication. Commands for read access do not use the command address, i.e. these commands may not be directed to a device based on the device address. There are two commands for read access, digLED_Read and digLED_Ping. The digLED_Read commands retrieve a status information from all devices and the digLED_Ping command is used to check the device chain’s integrity. Only the final node in the chain responds to a PING command. A digLED_Read command is first received by all devices via the frame in downstream direction. The last node in the chain then immediately transmits its response frame upstream. The response frame’s data field depends on the actual digLED_Read command. The response frame’s address field is set according to the own device’s address. All the nodes upstream forward all received response frames until a frame with the address of their adjacent node is received. Then the respective node transmits its own response frame. This procedure lasts until the chain’s first node has transmitted its response frame. A digLED_Ping command is similar to a digLED_Read command, but only the last device in the chain responds to a digLED_Ping. Thus, the digLED_Ping command is executed much faster than a regular digLED_Read command. Figure 15 - Single ended read command and responses Name Description Equation tDS_US Delay between down- and upstream tDS_CL + tUS_CL + 2 x n x tPD tRESP Delay between responses Oscillator variation of adjacent devices < ±30% Oscillator variation of adjacent devices > ±30% 0.43 x tUS_CL 0.7 x tUS_CL Table 18 - Down- and upstream delay, delay between responses |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |