39 / 84 page ![]() RPM-Based Fan Controller with HW Thermal Shutdown Datasheet SMSC EMC2103 39 Revision 0.85 (01-29-08) DATASHEET 5Ah R/W LUT Temp 4 Setting 2 Stores the threshold level for the Internal Diode channel (or Pushed Temp 2 temp) that is associated with the Drive 2 value 7Fh (127°C) LUT Lock Page 64 5Bh R/W LUT Drive 3 Stores the third programmed drive setting for the LUT D1h LUT Lock Page 64 5Ch R/W LUT Temp 1 Setting 3 Stores the threshold level for the External Diode 1 channel that is associated with the Drive 3 value 7Fh (127°C) LUT Lock Page 64 5Dh R/W LUT Temp 2 Setting 3 Stores the threshold level for the External Diode 2 channel that is associated with the Drive 3 value 7Fh (127°C) LUT Lock Page 64 5Eh R/W LUT Temp 3 Setting 3 Stores the threshold level for the External Diode 3 channel (or Pushed Temp 1 temp) that is associated with the Drive 3 value 7Fh (127°C) LUT Lock Page 64 5Fh R/W LUT Temp 4 Setting 3 Stores the threshold level for the Internal Diode channel (or Pushed Temp 2 temp) that is associated with the Drive 3 value 7Fh (127°C) LUT Lock Page 64 60h R/W LUT Drive 4 Stores the fourth programmed drive setting for the LUT BCh LUT Lock Page 64 61h R/W LUT Temp 1 Setting 4 Stores the threshold level for the External Diode 1channel that is associated with the Drive 4 value 7Fh (127°C) LUT Lock Page 64 62h R/W LUT Temp 2 Setting 4 Stores the threshold level for the External Diode 2 channel that is associated with the Drive 4 value 7Fh (127°C) LUT Lock Page 64 63h R/W LUT Temp 3 Setting 4 Stores the threshold level for the External Diode 3 channel (or Pushed Temp 1 temp) that is associated with the Drive 4 value 7Fh (127°C) LUT Lock Page 64 64h R/W LUT Temp 4 Setting 4 Stores the threshold level for the Internal Diode channel (or Pushed Temp 2 temp) that is associated with the Drive 4 value 7Fh (127°C) LUT Lock Page 64 65h R/W LUT Drive 5 Stores the fifth programmed drive setting for the LUT A7h LUT Lock Page 64 66h R/W LUT Temp 1 Setting 5 Stores the threshold level for the External Diode 1 channel that is associated with the Drive 5 value 7Fh (127°C) LUT Lock Page 64 67h R/W LUT Temp 2 Setting 5 Stores the threshold level for the External Diode 2 channel that is associated with the Drive 5 value 7Fh (127°C) LUT Lock Page 64 68h R/W LUT Temp 3 Setting 5 Stores the threshold level for the External Diode 3 channel (or Pushed Temp 1 temp) that is associated with the Drive 5 value 7Fh (127°C) LUT Lock Page 64 Table 6.1 EMC2103 Register Set (continued) ADDR R/W REGISTER NAME FUNCTION DEFAULT VALUE LOCK PAGE |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |