39 / 49 page ![]() MB89R112 DS411-00004-3v0-E 39 4. Command Execution Time 4-1. Write Single Block Command Execution Time The minimum time (processing in the Addressed mode) required to complete data writing to all user areas (8192 bytes) of the FeRAM and verification with the Write Single Block command is estimated to be 4.0 seconds. 4-2. Read Multiple Blocks Command Execution Time The minimum time (processing in the Addressed mode) required to complete data reading for all user areas (8192 bytes) of the FeRAM with the Read Multiple Blocks command is estimated to be 2.5 seconds. In addition, with the Fast Read Multiple Blocks command is estimated to be 1.3 seconds. |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|