10 / 30 page ![]() Write OTP Row Writing (only one time) in the OTP row (64 bytes) is enabled by an instruction. This instruction is composed of three specific Write operations of data bytes at three specific memory locations (each location in a different page) followed by the the data to store in the OTP row (refer to Table 4). When accessing the OTP row, the only LSB ad- dresses (A6 to A0) are decoded, with A6 = ’0’. Write the EEPROM Block Identifier The EEPROM block identifier can be written with a single Write operation with specific logic levels applied on A6 and the VID level on A9 (see Table 7). PROGRAM in the Flash BLOCK It should be noted that writing data into the EEPROM block and the Flash block is not per- formed in a similar way: the Flash memory requires an instruction (see Instruction chapter) for Erasing and another instruction for Programming one (or more) byte(s), the EEPROM memory is directly written with a simple operation (see Operation chapter). Program Instuction. During the execution of the Program instruction, the Flash block memory will not accept any further instructions. The Flash block memory can be programmed byte- by-byte. The program instruction is a sequence of three specific Write operations followed by writing the address and data byte to be programmed into the Flash block memory (see Table 4). The M39208 automatically starts and performs the programming after the fourth write operation. During programming, the memory status may be checked by reading the status bits DQ5, DQ6 and DQ7, as detailed in the following sections. READ DQ5 & DQ7 at VALID ADDRESS START READ DQ7 FAIL PASS AI01369 DQ7 = DATA YES NO YES NO DQ5 = 1 DQ7 = DATA YES NO Figure 6. Data Polling Flowchart READ DQ5 & DQ6 START READ DQ6 FAIL PASS AI01370 DQ6 = TOGGLE NO NO YES YES DQ5 = 1 NO YES DQ6 = TOGGLE Figure 7. Data Toggle Flowchart 10/30 M39208 |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |