| Motore di ricerca datesheet componenti elettronici |
|
WHECSV Scheda tecnica(PDF) 10 Page - Whirlpool. |
|
|
|||||||||||||||||||||||||||||
WHECSV Scheda tecnica(HTML) 10 Page - Whirlpool. |
|
10 / 32 page ![]() 10 MOVE THE WATER SOFTENER INTO PLACE 1. Move the water softener into the desired location. Set it on a solid, level surface. IMPORTANT: Do not place shims directly under the salt storage tank to level the softener. The weight of the tank, when full of water and salt, may cause the tank to fracture at the shim. 2. Visually check and remove any debris from the water softener valve inlet and outlet ports. 3. Make sure the turbine assembly spins freely in the “out” port of the valve. 4. If not already done, put a light coating of silicone grease on the single bypass valve o-rings. 5. Push the single bypass valve into the softener valve as far as it will go. Snap the two large holding clips into place, from the top down as shown in Figures 11 & 12. IMPORTANT: Be sure the clips snap firmly into place so the single bypass valve will not pull out. Excessive Weight Hazard Use two or more people to move and install or uninstall water softener. Failure to do so can result in back or other injury. TURN OFF WATER SUPPLY 1. Close the main water supply valve, located near the well pump or water meter. 2. Open all faucets to drain all water from house pipes. NOTE: Be sure not to drain water from the water heater, as damage to the water heater elements could result. INSTALL THE BRINE TANK OVERFLOW ELBOW Install the brine tank overflow grommet and elbow in the 13/16" diameter hole in the back of the salt storage tank sidewall. NOTE: The brine tank overflow elbow accepts either 1/2" or 3/8" I.D. hose. Installation Instructions FIG. 12 CORRECT ASSEMBLY Clip Outside diameter of clip channel on single bypass valve Outside diameter of water softener valve inlet & outlet NOTE: Be sure all 3 tabs of the clip go through the matching holes on the water softener valve inlet or outlet, and fully into the channel on the single bypass valve. Make sure that the tabs are fully seated. FIG. 11 Clip Channel Single Bypass Valve FIG. 10 Top Cover Salt Lid Salt Storage Tank Brine Tank Overflow Elbow Brine Tank Overflow Grommet 13/16" Hole |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |