| Motore di ricerca datesheet componenti elettronici |
|
TC10 LAB Scheda tecnica(PDF) 4 Page - Wavelength Electronics, Inc. |
|
|
|||||||||||||||||||||||||||||
TC10 LAB Scheda tecnica(HTML) 4 Page - Wavelength Electronics, Inc. |
|
4 / 29 page ![]() 4 QUICK CONNECT GUIDE CONNECT THE POWER On the back panel, insert the female end of the IEC AC power cable into the Power receptacle and then plug the male end into the AC power source. NOTE: Place the TC LAB instrument at least 6” away from any wall to provide adequate ventilation and prevent overheating. WIRE A TEST LOAD We recommend using a test load and simulated thermistor when configuring the TC LAB instrument. The thermistor test load simulates a 10 kΩ thermistor operating at 25ºC. Wire a test load to a 15 + 2 D-SUB plug and insert the plug into the TE Out and Sensor D-SUB port located on the back panel. 10 kΩ SENSOR- (1) SENSOR+ (2) R LOAD Recommendation 0 to 10 A: 0.5 Ω, > 50 W 0 to 15 A: 0.1 Ω, > 50 W Resistors may require heatsinking. R LOAD TEC+ (A1) TEC- (A2) Test Load Thermistor Test Load Figure 1. Test Load Wiring Schematic Setting up this test load allows current to be driven to either the positive or negative limit. Choose units of resistance and change the setpoint above or below the 10 kΩ value. This confirms proper operation and direction of the current flow. TURN ON POWER 1. Press the Power switch on the back panel to the | position. The front panel power button light slowly pulses. 2. Press the Power button on the front panel, the button illuminates, touchscreen is activated, and the Control Screen is active. NOTE: Turning off front Power button powers down the application electronics and puts the unit into Standby mode. Turning off rear Power switch powers down all electronics and some settings return to factory default. SET THE LIMITS 1. Press to access the Limit Screen. 2. On the Limit Screen, press the blue Limit Current values and rotate the adjustment knob to change to the desired values. The instrument will beep when set. Temperature limits can be set on this screen. The setpoint is restricted by these limits. The positive and negative current settings indicate the direction of flow during heating and cooling. CHOOSE A CONTROL SENSOR 1. Press to access the Sensor Screen. 2. Press the Sensor Type value and turn the adjustment knob to cycle through the factory defaults or any user-defined sensors. Choose the sensor to match the test load or the appropriate sensor for the test load. Additionally, thermistors require choosing the correct bias current. The test load suggested by Wavelength uses a 10 kΩ 100 µA thermistor configuration. ADJUST SETPOINT 1. Press to access the Control Screen. 2. Press the blue Setpoint temperature value and turn the adjustment knob to change it. The instrument will beep when set. NOTE: The Control Screen is on by default when the instrument is turned on. The Control Screen is also the location of the PID control parameters, IntelliTune (intelligent autotune), and the Temperature Scan function. To change any of the PID values, press the number and turn the adjustment knob until the desired value is displayed. |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |