| Motore di ricerca datesheet componenti elettronici |
|
E5CC-RX2DBM-000 Scheda tecnica(PDF) 124 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E5CC-RX2DBM-000 Scheda tecnica(HTML) 124 Page - Omron Electronics LLC |
|
124 / 138 page ![]() E5 @C/E5@C-T 124 23.Do not disconnect the Communications Conversion Cable or the USB-Serial Conversion Cable while communications are in progress. Damage or malfunction may occur. 24.Do not touch the external power supply terminals or other metal parts on the Digital Temperature Controller. 25.Do not exceed the communications distance that is given in the specifications and use the specified communications cable. Refer to the E5 @C Digital Temperature Controllers User’s Manual (Cat. No. H174) for information on the communications distances and cables for the E5 @C. For details on the E5 @C-T, refer to the E5 @C-T Digital Temperature Controllers Programmable Type User’s Manual (Cat. No. H185). 26.Do not bend the communications cables past their natural bending radius. Do not pull on the communications cables. 27.Do not turn the power supply to the Digital Temperature Controller ON or OFF while the USB-Serial Conversion Cable is connected. The Digital Temperature Controller may malfunction. 28.Make sure that the indicators on the USB-Serial Conversion Cable are operating properly. Depending on the application conditions, deterioration in the connectors and cable may be accelerated, and normal communications may become impossible. Perform periodic inspection and replacement. 29.Connectors may be damaged if they are inserted with excessive force. When connecting a connector, always make sure that it is oriented correctly. Do not force the connector if it does not connect smoothly. 30.Noise may enter on the USB-Serial Conversion Cable, possibly causing equipment malfunctions. Do not leave the USB-Serial Conversion Cable connected constantly to the equipment. 31.For the E5DC/E5DC-B, when you attach the Main Unit to the Terminal Unit, make sure that the hooks on the Main Unit are securely inserted into the Terminal Unit. 32.For the E5CC-U, when you attach the Main Unit to the socket, make sure that the hooks on the socket are securely inserted into the Main Unit. 33.Install the DIN Track vertically to the ground. 34.For the E5DC/E5DC-B, always turn OFF the power supply before connecting the Main Unit to or disconnecting the Main Unit from the Terminal Unit, and never touch nor apply shock to the terminals or electronic components. When connecting or disconnecting the Main Unit, do not allow the electronic components to touch the case. 35.Observe the following precautions when you remove the terminal block or pulling out the interior of the product of the E5GC. • Always follow the instructions provided in the E5 @C Digital Temperature Controllers User’s Manual (Cat. No. H174). • Turn OFF the power supply before you start and never touch nor apply shock to the terminals or electric components. When you insert the interior body of the Digital Temperature Controller, do not allow the electronic components to touch the case. • Check for any corrosion on the terminals. • When you insert the interior body into the rear case, confirm that the hooks on the top and bottom are securely engaged with the case. 36.Observe the following precautions when you wire the E5 @C-B. • Always follow the wiring instructions provided in Wiring Precautions for E5 @C-B (Controllers with Push-In Plus Terminal Blocks) on page 133. • Do not wire anything to the release holes. • Do not tilt or twist a flat-blade screwdriver while it is inserted into a release hole on the terminal block. The terminal block may be damaged. • Insert a flat-blade screwdriver into the release holes at an angle. The terminal block may be damaged if you insert the screwdriver straight in. • Do not allow the flat-blade screwdriver to fall out while it is inserted into a release hole. • Do not bend a wire past its natural bending radius or pull on it with excessive force. Doing so may cause the wire to break. • Do not use crossover wiring except for the input power supply and communications. • Do not use crossover wiring for the E5CC-B/E5EC-B except for the input power supply and communications. Do not use crossover wiring for the E5DC-B. The E5CC, E5CC-B, E5CC-U, E5EC, E5EC-B, E5AC, and E5DC comply with Lloyd's standards. When applying the standards, the following installation requirements must be met in the application. Also insert the Waterproof Packing on the backside of the front panel. Application Conditions Installation Location The E5CC, E5CC-B, E5CC-U, E5EC, E5EC-B, E5AC, and E5DC comply with installation category ENV1 and ENV2 of Lloyd's standards. Therefore, they must be installed in a location equipped with air conditioning. They cannot be used on the bridge or decks, or in a location subject to strong vibration. Service Life 1. Use the product within the following temperature and humidity ranges: Temperature: -10 to 55°C (with no icing or condensation) Humidity: 25% to 85% If the product is installed inside a control board, the ambient temperature must be kept to under 55°C, including the temperature around the product. 2. The service life of electronic devices like Digital Temperature Controllers is determined not only by the number of times the relay is switched but also by the service life of internal electronic components. Component service life is affected by the ambient temperature: the higher the temperature, the shorter the service life and, the lower the temperature, the longer the service life. Therefore, the service life can be extended by lowering the temperature of the Digital Temperature Controller. 3. When two or more Digital Temperature Controllers are mounted horizontally close to each other or vertically next to one another, the internal temperature will increase due to heat radiated by the Digital Temperature Controllers and the service life will decrease. In such a case, use forced cooling by fans or other means of air ventilation to cool down the Digital Temperature Controllers. When providing forced cooling, however, be careful not to cool down the terminals sections alone to avoid measurement errors. Shipping Standards Precautions for Correct Use |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |