| Motore di ricerca datesheet componenti elettronici |
|
H400D Scheda tecnica(PDF) 18 Page - OSRAM GmbH |
|
|
|||||||||||||||||||||||||||||
H400D Scheda tecnica(HTML) 18 Page - OSRAM GmbH |
|
18 / 24 page ![]() 18 TS 44842 OSRAM / POWERSTAR HQI 106 T001 GB 4/24.5.2007 Please note: The values and curves published in this document are for guidance only. The basic data was determined under controlled laboratory conditions for a switching cycle of 11 h on/1 h off. There may be considerable differences in actual practice. The highlighted areas around the curves represent a 0% confidence range based on our test conditions. NIOSH threshold and ACGIH UV output: The radiated energy of a lamp is indicated by the defined NIOSH curve. The NIOSH effective radiated output calculated from this is converted into permitted exposure times with defined limit values. The ACGIH UV output value correlates directly with the NIOSH value and represents the current required value for UV exposure. PF correction capacitor: The pf correction capacitors are designed so that cos w ≥ 0. is achieved at rated voltage. Operating instructions Supply voltage: The lamps must be connected via suitable control gear. A 240 V / 50 Hz ac supply is generally required. If a different supply voltage is used (e.g. 400 V / 50 Hz) control gear with appropriate taps must be used. Permitted mains voltage deviation: ± 3% Sudden fluctuations in mains voltage of more than 10% may cause the lamps to go out. If the deviation from rated supply voltage (20 V or 400 V) is permanent, high-pressure discharge lamps may exhibit changes in colour or luminous flux. Lamp life may also be reduced. Control gear: Conventional control gear: Choke, igniter and pf correc- tion capacitor. The right igniter for the particular lamp type must be used to ensure reliable and safe ignition. Igniters must always be installed close to the lamp. The choke may be installed any distance from the lamp, provided the permissible voltage drop is not exceeded. For power supplies with a neutral conductor the choke should be connected to the live conductor. In the case of luminaires in which there are no lamps installed, the igni- tion equipment (igniter, ignition pulser) must be disabled when voltage is applied otherwise the igniters may pro- duce radio interference. The chokes and pf correction capacitors generally needed for operating discharge lamps may, under certain condi- tions, create oscillating circuits. These circuits may then produce excessive currents and voltages, which in turn can destroy the lamps, ballasts and capacitors. Such resonance phenomena must be avoided by appropriate circuits and fuses. When high-pressure discharge lamps come to the end of their lives a rectifier effect may occur (see IEC 6205). This is not manufacturer-specific. Because of the exces- sive dc current components the ballasts and igniters may become overheated. High-pressure discharge lamps should therefore only be operated with control gear with thermal protection. This applies also to control gear with the option of power reduction. The following lamps with integrated igniters will start on mains voltage: c HQI®-T 2000 /D/I c HQI®-T 2000 /N The lamps must not be operated with integrated igniters in luminaires equipped with igniters. Suitable igniters and control gear for POWERSTAR® are available from the electrical industry. In the case of igniters equipped with OSRAM switching element SE 600 (built-in spark gap), SE 600 must be replaced each time the lamp is replaced. Operating temperatures: Only high-pressure discharge lamps with external igniters are suitable for low-temperature applications down to – 50 °C. Such applications call for special (heatable) igniters such as MZN 400 SU-LT from BAG Turgi (for lamps from 100 to 400 W). Power factor: CCG: Because of the series connected choke this is around 0.5 to 0.7 (without compensation) ECG: If POWERTRONIC® is used the power factor is greater than 0.6. Compensation is therefore not needed here. Switching on: Full luminous flux is reached only a few minutes after the lamp is switched on. The start-up current may be up to twice the operating current depending on the control gear. (See also the graphs on p. 21) |
|
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |