| Motore di ricerca datesheet componenti elettronici |
|
V54C365164VC Scheda tecnica(PDF) 8 Page - Mosel Vitelic, Corp |
|
|
|||||||||||||||||||||||||||||
V54C365164VC Scheda tecnica(HTML) 8 Page - Mosel Vitelic, Corp |
|
8 / 54 page ![]() MOSEL VITELIC V54C365164VC 8 V54C365164VC Rev. 0.8 July 2001 Burst Length and Sequence: Refresh Mode SDRAM has two refresh modes, Auto Refresh and Self Refresh. Auto Refresh is similar to the CAS -before-RAS refresh of conventional DRAMs. All of banks must be precharged before applying any re- fresh mode. An on-chip address counter increments the word and the bank addresses and no bank infor- mation is required for both refresh modes. The chip enters the Auto Refresh mode, when RAS and CAS are held low and CKE and WE are held high at a clock timing. The mode restores word line after the refresh and no external precharge command is necessary. A minimum tRC time is re- quired between two automatic refreshes in a burst refresh mode. The same rule applies to any access command after the automatic refresh operation. The chip has an on-chip timer and the Self Re- fresh mode is available. It enters the mode when RAS, CAS, and CKE are low and WE is high at a clock timing. All of external control signals including the clock are disabled. Returning CKE to high en- ables the clock and initiates the refresh exit opera- tion. After the exit command, at least one tRC delay is required prior to any access command. DQM Function DQM has two functions for data I/O read and write operations. During reads, when it turns to “high” at a clock timing, data outputs are disabled and become high impedance after two clock delay (DQM Data Disable Latency tDQZ ). It also provides a data mask function for writes. When DQM is acti- vated, the write operation at the next clock is prohib- ited (DQM Write Mask Latency tDQW = zero clocks). Suspend Mode During normal access mode, CKE is held high en- abling the clock. When CKE is low, it freezes the in- ternal clock and extends data read and write operations. One clock delay is required for mode entry and exit (Clock Suspend Latency tCSL). Power Down In order to reduce standby power consumption, a power down mode is available. All banks must be precharged and the necessary Precharge delay (trp) must occur before the SDRAM can enter the Power Down mode. Once the Power Down mode is initiated by holding CKE low, all of the receiver cir- cuits except CLK and CKE are gated off. The Power Down mode does not perform any refresh opera- tions, therefore the device can’t remain in Power Down mode longer than the Refresh period (tref) of the device. Exit from this mode is performed by tak- ing CKE “high”. One clock delay is required for mode entry and exit. Auto Precharge Two methods are available to precharge SDRAMs. In an automatic precharge mode, the CAS timing accepts one extra address, CA10, to determine whether the chip restores or not after the Burst Length Starting Address (A2 A1 A0) Sequential Burst Addressing (decimal) Interleave Burst Addressing (decimal) 2 xx0 xx1 0, 1 1, 0 0, 1 1, 0 4x00 x01 x10 x11 0, 1, 2, 3 1, 2, 3, 0 2, 3, 0, 1 3, 0, 1, 2 0, 1, 2, 3 1, 0, 3, 2 2, 3, 0, 1 3, 2, 1, 0 8 000 001 010 011 100 101 110 111 0 1 2 3 4 5 6 7 1 2 3 4 5 6 7 0 2 3 4 5 6 7 0 1 3 4 5 6 7 0 1 2 4 5 6 7 0 1 2 3 5 6 7 0 1 2 3 4 6 7 0 1 2 3 4 5 7 0 1 2 3 4 5 6 0 1 2 3 4 5 6 7 1 0 3 2 5 4 7 6 2 3 0 1 6 7 4 5 3 2 1 0 7 6 5 4 4 5 6 7 0 1 2 3 5 4 7 6 1 0 3 2 6 7 4 5 2 3 0 1 7 6 5 4 3 2 1 0 Full Page nnn Cn, Cn+1, Cn+2,..... not supported |
|
Link URL |
| Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | Collegamento alla scheda tecnica | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |